Product Description and Electrical Requirements
Dimensions (cm)
w x d x h
Model
Electrical
Use condenser
Maximum
Fuse Size
57.7*** x 61 x 58.5
C0522MR-6
230/50/1
ERC111-6
15
same
same
same
ERC211-6**
15
78*** x 61 x 58.5
C0530MR-6
same
ERC111-6
15
same
same
same
ERC211-6**
15
same
C0630MR-6
same
ERC311-6
20
78*** x 61 x 74
C0830MR-6
same
ERC311-6
30
same
C1030MR-6
same
ERC311-6
20
** ERC211 has two circuits, when two C0522s or
C0530s are connected to it, fan motor relay kit
KCMR-230 must be used to control the fan motor.
*** Maximum width at top panel.
Ratings include the remote condenser motor, as it
is designed to be powered by the ice machine. If
connecting remote condenser independently of the
ice machine, use the information on the
condenser's dataplate for fuse and wire sizes.
Table notes: Medium cube models have the same
electrical characteristics as Small. Series revision
code omitted. All the listed condensers include a
headmaster valve.
Precharged tubing kits:
The ice making head’s and the remote condenser’s
refrigeration circuits must be connected. They are
designed to be connected using precharged
refrigerant tubing, supplied in kits of liquid and
discharge tubes. Several lengths are available,
order the one that just exceeds the length needed
for the site.
3 meters
6 meters
12 meters
22 meters
RTE10
RTE20
RTE40
RTE75
No additional refrigerant is required.
Note: Refrigerant charge is supplied with the ice
machine.
June 2007
Page 6
C0522 through C1030
Remote Condenser Models - Installation Manual