C0
32
2 –
3
00
lb
C
ub
e Ic
e M
ac
hin
e
Scotsman Ice Systems
775 Corporate Woods Parkway
Vernon Hills, IL 60061
1-800-SCOTSMAN
Fax: 847-913-9844
E-mail: [email protected]
www.scotsman-ice.com
© 2007 Scotsman Ice Systems.
The Smart Choice in Ice.
TM
TM
SIS-SS-PRD-C0322 8-07
Specifications
All Models
208-230/60/1
2
2.6
15
Operating Requirements
Maximum
Minimum
Air Temperatures
Water Temperatures
Remote Cond. Temps
Water Pressures
Electrical Voltage
50°F (10°C)
40°F (4.4°C)
-20°F (-29°C)
20 PSIG (1.4 bar)
-10%
100°F (38°C)
100°F (38°C)
120°F (49°C)
80 PSIG (5.5 bar)
+10%
* 208-230/60/1 Voltage - Substitute “-32” in place of “-1”, i.e. C0322SA-32A.
KVS
KSB
KSB-N
Vari-Smart™ Ice Level Control -
Program ice bin levels to match ice needs.
Smart-Board™ Advaced Control -
Use additional operational data for fast diagnosis.
Smart-Board™ Advanced Control with Network -
Network capable.
sm
.
m
ed.
C0322 on B322 bin.
22” Prodigy plan view.
Dimensions (W x D x H):
Unit:
22” x 24” x 23”
(55.9 x 61.0 x 58.4 cm)
Shipping Carton:
25.5” x 27.5” x 28”
(64.8 x 69.9 x 71.1 cm)
Shipping Weight:
145 lb / 66 kg
BTUs per hour:
5,200
Accessories
Model Number
Description
* Scotsman recommends all ice machines have water filtration. See Scotsman Sanitation Matrix for details.
Model Number*
Cube Size: medium or small
Condenser
Unit
Basic Electrical
Volts/Hz/Phase
Max. Fuse Size
or HACR Circuit
Breaker (amps)
Circuit
Wires
Min. Circuit
Ampacity
Energy Consumption
kWh/100 lb (45.4 kg)
90˚F(32˚C)/70˚F(21˚C)
Water Usage
Gallons/100 lb (liters/45.4 kg)
Potable
90˚F(32˚C)/
70˚F(21˚C)
Condenser
90˚F(32˚C)/
70˚F(21˚C)
Ultrasonic
Bin Level
Sensor
(Optional)
7.00”
(17.8 cm)
22.00”
(55.9 cm)
19.05”
(48.4 cm)
24.00”
(61 cm)
Ice
D
ro
p O
pe
ni
ng
2.00”
(5.1 cm)
2.00”
(5.1 cm)
3.25”
(8.3 cm)
10.25”
(26 cm)
Electrical
Entrance
3/8” FPT
Machine
Water In
3/4” FPT
Machine
Drain
34.00”
(86.4 cm)
MAX.
3/4” FPT
Bin Drain
6.00”
(15.2 cm)
22.00”
(55.9 cm)
3/8” FPT
Condenser
Outlet
WC Units Only
44.00”
(111.8 cm)
3/8” FPT
Condenser
Inlet
WC Units Only
23.00”
(58.4 cm)
24.00”
(61.0 cm)
Intake
Air
Exhaust Air
(AC Units Only)
Installation Note: Allow 6” space at left, back and right side for ventilation and utility connections.
C0322MA-1A
C0322MW-1A
C0322SA-1A
C0322SW-1A
Air
Water
Air
Water
115/60/1
115/60/1
115/60/1
115/60/1
15
15
15
15
2
2
2
2
12.7
11.9
12.7
11.9
6.6
4.7
6.6
4.7
19.0/72.0
18.3/69.4
19.0/72.0
18.3/69.4
-
138.0/523.3
-
138.0/523.3
Specifications and design are subject to change without notice.