background image

C0

32

2 –

 3

00

 lb

 C

ub

e Ic

e M

ac

hin

e

Scotsman Ice Systems
775 Corporate Woods Parkway
Vernon Hills, IL 60061

1-800-SCOTSMAN
Fax: 847-913-9844
E-mail: [email protected]

www.scotsman-ice.com

© 2007 Scotsman Ice Systems.

The Smart Choice in Ice.

TM

TM

SIS-SS-PRD-C0322   8-07

Specifications

All Models

208-230/60/1

2

2.6

15

Operating Requirements

Maximum

Minimum

Air Temperatures
Water Temperatures
Remote Cond. Temps 
Water Pressures
Electrical Voltage

50°F (10°C)
40°F (4.4°C)
-20°F (-29°C)
20 PSIG (1.4 bar)
-10%

100°F (38°C)
100°F (38°C)
120°F (49°C)
80 PSIG (5.5 bar)
+10%

* 208-230/60/1 Voltage - Substitute “-32” in place of “-1”, i.e. C0322SA-32A.

KVS
KSB
KSB-N

Vari-Smart™ Ice Level Control - 

Program ice bin levels to match ice needs.

Smart-Board™ Advaced Control - 

Use additional operational data for fast diagnosis.

Smart-Board™ Advanced Control with Network - 

Network capable.

sm

.

m

ed.

C0322 on B322 bin.

22” Prodigy plan view.

Dimensions (W x D x H):
Unit:

 

22” x 24” x 23” 

 

(55.9 x 61.0 x 58.4 cm)

Shipping Carton:

 

25.5” x 27.5” x 28”

 

(64.8 x 69.9 x 71.1 cm)

Shipping Weight: 
 

145 lb / 66 kg

BTUs per hour: 
 

5,200

Accessories

Model Number

Description

* Scotsman recommends all ice machines have water filtration.  See Scotsman Sanitation Matrix for details.

Model Number*

Cube Size: medium or small

Condenser

Unit

Basic Electrical

Volts/Hz/Phase

Max. Fuse Size

or HACR Circuit 

Breaker (amps)

Circuit

Wires

Min. Circuit

Ampacity

Energy Consumption

kWh/100 lb (45.4 kg)

90˚F(32˚C)/70˚F(21˚C)

Water Usage 

Gallons/100 lb (liters/45.4 kg)

Potable

90˚F(32˚C)/

70˚F(21˚C)

Condenser

90˚F(32˚C)/

70˚F(21˚C)

Ultrasonic 

Bin Level 

Sensor 

(Optional)

7.00”

(17.8 cm)

22.00”

(55.9 cm)

19.05”

(48.4 cm)

24.00”

(61 cm)

Ice

 D

ro

p O

pe

ni

ng

2.00”

(5.1 cm)

2.00”

(5.1 cm)

3.25”

(8.3 cm)

10.25”

(26 cm)

 

 

Electrical

Entrance

3/8” FPT

Machine

Water In

3/4” FPT

Machine

Drain

34.00”

(86.4 cm)

MAX.

3/4” FPT

Bin Drain

6.00”

(15.2 cm)

22.00”

(55.9 cm)

3/8” FPT

Condenser

Outlet

WC Units Only

44.00”

(111.8 cm)

3/8” FPT

Condenser

Inlet

WC Units Only

23.00”

(58.4 cm)

24.00”

(61.0 cm)

Intake

Air

Exhaust Air

(AC Units Only)

Installation Note: Allow 6” space at left, back and right side for ventilation and utility connections.

C0322MA-1A
C0322MW-1A
C0322SA-1A
C0322SW-1A

Air

Water

Air

Water

115/60/1
115/60/1
115/60/1
115/60/1

15
15
15
15

2
2
2
2

12.7
11.9
12.7
11.9

6.6
4.7
6.6
4.7

19.0/72.0
18.3/69.4
19.0/72.0
18.3/69.4

-

138.0/523.3

-

138.0/523.3

Specifications and design are subject to change without notice.