6.0 Using the Programming Card
All parameters of the esc can be changed via the
program card.
To program any function on the card you must follow the
following procedure:
6.1
Press a function button
6.2
enter a numeric value
6.3
Enter to complete
Example Low Voltage Cut to enter 9.5V Press “LVC” Press
“0” Press “9” Press “5” then “ENTER” If successful a DI
DOO sound will come from the motor and the LED will
Flash RED. An invalid option will not get any confirmation
sound from the motor and the LED will not flash
Please note that there is a time limit from when you press a
function button the numeric values and enter if you go over this
time limit no sound of flashes will come from the esc
Function Button
Numeric
Value
What it does
Example from
Above
095
Sets Low Voltage Cut to
9.5Volts
LVC
(Low Voltage Cut)
050-250
Low Voltage Cut 050 (5V) to
250(25V) in .5V increments.
*6V
BRK
(Brake Setting)
1*
2
3
4
5
* No brake
Very soft brake
Soft Brake
Hard Brake
Very Hard Brake
AIR
1*
Activate Airplane mode
PCT
Program Cut Type
(LVC type)
1*
2
3
Cut 50% of maximum power
No Cut just LED warning
Pulse warning
MAT
Motor
Acceleration Time
Delay
1*
2
3
4
5
0.15 second
0.3sec
0.45sec
0.7sec
1.3 sec
CAR/B
Car/Boat mode
1
2
No reverse
With reverse (brake preset)
COP
Current Overload
Protection
1*
2
Protection on
Protection off (this option will
void warranty
FREQ
Drive Frequency
1*
2
8khz (recommended for most
Brushless motors)
3
18khz (for use with low
inductance motors)
32khz (for use with VERY low
inductance motors)
SS
Soft Start
1
2
Soft start with out governor for
use when plugged into throttle
channel 12 second delay to
50% of set speed.
Soft start with governor mode
(see GOV function) Requires use
of a spare channel other then
the throttle channel
RO
Motor Rotation
direction
1*
2
Clockwise
Counter clock wise
TIM
Motor Timing
1*
2
3
4
5
6
Auto Timing
5°
15°
20°
25°
30°
GOV
Governor
50
60
70
80
90
50%RPM
60%RPM
70%RPM
80%RPM
90%RPM
SB
Motor Start Booster
1
2*
ON
OFF
ENTER
Enter value send signal to ESC
OTHER
All other keys are reserved for
future programming options
*Factory Default
7.0 Lights and Sounds
Your ESC will emit different lights and sounds according to
the function it is applying below is a table of the following
conditions:
No Signal from
receiver at startup
LED light will flash orange with constant 2
warning tone. If Using program card, the LED will
flash red and emit 3 beep tones then you will
enter setup mode
Loss of signal during
operation
LED will flash red with a 2 beep warning tone
Over temperature
during power up
(>60°C)
LED will be constant red with 2 beep warning
tone. To restart, disconnect power source, wait
for cool down then re-connect.
Over heat during
operation (>85 °C)
Power reduced to half throttle , red LED will flash.
To reset throttle must be put into idle position
Power on low
voltage warning
LED will flash red quickly with beep warning tone
when voltage is low than the preset cut-off
voltage.
Low voltage cut
warning
When voltage is lower than preset cut off voltage,
red LED will flash rapidly red.
Over Amp Protection Is only activated at over 50% throttle during over-
amp protection, LED will flash red rapidly
Governor Limit
Warning
If governor reaches 100% throttle, orange LED
light turn on.
Soft start indication
Orange LED light will turn off automatically when
soft start has been deactivated.