15
Alarm Triggers
When the system is triggered, the siren will sound and the turn signal lights will flash. The transceiver’s
LCD will display the following messages:
1.
If bike is bumped, the LCD will display
icon. The siren on the bike will sound for 5
seconds and the lights will flash. This cycle will repeat twice.
2.
If the perimeter sensor triggers a full alarm cycle, the LCD will display icon. The siren on
the bike will sound for 5 seconds. This cycle will repeat twice
(Note: The turn signal lights will not flash for a perimeter sensor trigger).
3.
If the bike is tilted, the LCD will display icon. The siren on the bike will sound for 30
seconds and the lights will flash. This cycle will repeat six times.
4.
If the ignition switch is turned on or tampered with, the LCD will display
Icon. The siren on
the bike will sound for 30 seconds and the lights will flash. This cycle will repeat six times.
5.
If the main harness or battery power supply is disconnected (assuming optional Back-Up
battery is installed), the LCD will display icon. The MCM-9 will still continue to sound
and transmit from its internal power source. The siren on the bike will sound for 30 seconds.
This cycle will repeat six times.
6.
The transceiver will continue to flash the triggered icon until any button is pressed.
Transceiver Information
12
Button 1
Encoding a Transceiver
1.
Unplug HAR-1 from the MCM-9 and plug it back in, the siren will chirp 2 times and the lights
will flash 2 times.
2.
Within 6 seconds of plugging in the HAR-1 turn ignition switch “ON” and “OFF” 3 times.
3.
If step 2 is done correctly and within the time allowed , the siren will chirp 2 times and the
lights will flash an additional 2 times to confirm that the system is in “Learn Mode”.
4.
Press and hold button 1 until the system chirps 2 times and the lights flash 2 times to
indicate that the MCM has learned the code. The transceiver echoes 4 chirps and the LCD
displays [
LErn donE
] to confirm that the transceiver is encoded.
5.
If you are encoding a second transceiver repeat step number 4 for the second transceiver
before continuing to step number six.
6.
Turn ignition “ON” and “OFF” to exit “Learn Mode”.
Note: The transceivers are programmed from the factory. Encoding is only necessary should
the transceiver lose its code and will not arm or disarm the security system or if a second