Programming Software Installation. 

Do not connect the Base Programmer unit until the software has been installed and the required USB drivers 
have been installed. 

 

Software 

Insert the CD supplied with the unit and allow the auto run function to complete. Select “Install PND Software” option 
and allow the software to install to the default location unless there is a good reason not to do so. A standard set up file 
is also included in the installation. 

Drivers 

When the installation has finished, select the “Install USB drivers option” and allow the software to install. 

The user manual is installed as a Windows compiled help file that can be used in conjunction with the software. 
 

Software Start. 

 
Connect the device to the USB port via the supplied cable , ensure that the Red LED is on and the green LED is flashing 
every 2 seconds, this indicates that the device is ready to accept configuration parameters. If the LED's are not 
on/flashing at the required rate remove the USB cable and reconnect. If the LED is still not flashing then there is a 
potential problem with the device, contact technical support for further information. 

Note:- Do not disconnect the device from the USB port while a read from device or write to device is in progress 
as this could cause the device to stop functioning.
 Please ensure all other Scope USB devices are disconnected.  

From the Start/Programs/Scope menu select the Base Pendant Programmer to start the configuration program for 
the Pendant module. 

The software will detect the device connected, interrogate it and if validated will start up as shown below. The software 
can detect when the connection has been broken and will detect when the device is reconnected. 

Note that the command window indicates when the Pendant is verified. The device number and the Com port that it is 
associated with is shown in the right hand section of the software. If the Com port number is not shown, this indicates 
that the drivers are not installed properly or the wrong drivers are installed. If this is the case, please reinstall the drivers 
from the CD. Ensure the software indicates the device is connected. 

Note: 2 text files called User and Region are also required in the installation, these are automatically loaded at 
program start. Please do not try to alter these files as they are encrypted. 

FTDI Driver Test List 

 

Version   

Date   

Released  

Comments  

CDM      

2.00.00   

May 18th 2006  First stable release used by scope. Issued as an exe Install file. 

 

CDM      

2.04.16   

Feb 17th 2009   Tested and released with application software. Issue as an exe 

 

 

 

 

 

 

Install file. 

CDM      

2.04.22   

Nov 3rd 2009   Current driver set and recommended for new installs. 

 

 

 

 

 

 

 

CDM      

2.08.02   

Aug 11th 2010   Tested with Current application firmware. 

 
CDM      

2.08.14   

April 12th 2011   Most recent non beta version of the drivers. 

 

 

 

 

 

 

Users should upgrade to this driver version. 

 
 

Please note FTDI drivers are continuously being updated. Your PC may already contain drivers for FTDI Devices. 
Scope application software has been tested with the drivers allocated on the software package disk and selected 
previous driver releases. The driver test list is shown above. 

 

 

 

 

 

Содержание MPA3

Страница 1: ...A3 Page 1 of 11 Issue 1 MPA3 Mobile Personal Alarm MK3 User Manual Scope Communications UK Ltd Quantum House Totnes Devon TQ9 5AL United Kingdom Tel 44 0 1803 860700 Fax 44 0 1803 863716 www scope uk com ...

Страница 2: ...ditions available upon request Licence For the UK this equipment is intended for use on the 433 and 458 MHz Short Range Device licence exempt radio frequencies and programming has been restricted to these ranges For use in the USA this equipment will require a licence Consult your dealer for further advice For further technical rules governing the use of this equipment you should obtain the FCC Ru...

Страница 3: ...d of suitable test equipment etc enabling the system performance to be compared with the original installation data The frequency of the tests required will vary between applications If portable equipment has been dropped or is worn by a person involved in an accident the unit should be tested again before re use It must be stressed that the physical range tests are essential and that any construc...

Страница 4: ...itness for a particular purpose In no event will Scope or any of its agents be liable for direct indirect special incidental or consequential damages resulting from any defect in the product even if advised of the possibility of such damages The warranties and remedies set forth above are exclusive and in lieu of all others oral or written expressed or implied No Scope distributor dealer agent or ...

Страница 5: ...cancel mode 3 axis accelerometer for Fall Detection Shock Detection Motion Detection or Tilt Detection Call cancelling using magnetic wand Configurable Test Call timer function Note This is a low power device designed to for long life and minimal power consumption Device settings can have a considerable impact on the battery life 3 Ancillary devices accompany the MPA if required An MPA programmer ...

Страница 6: ...3 seconds the accelerometer is switched off so that the unit can be placed in sleep mode when not being used When the magnet is held to the side of the case for more than 3 seconds again then the accelerometer is turned back on A message is transmitted to confirm the current state of the accelerometer If the device has not been configured to use the accelerometer then the Accelerometer off message...

Страница 7: ...nit is done by the application software and a Pendant programmer unit The pendant programmer provides a docking station for the pendant and a contact less method of unit configuration The unit cannot be read in this programmer unit only written to Pendants can be factory configured to customer requirements If the MPA3 configuration needs to be read generally only a factory function the MPA3 can be...

Страница 8: ...iguration program for the Pendant module The software will detect the device connected interrogate it and if validated will start up as shown below The software can detect when the connection has been broken and will detect when the device is reconnected Note that the command window indicates when the Pendant is verified The device number and the Com port that it is associated with is shown in the...

Страница 9: ...onfigured Via Pendant Programmer Accelerometer 3 axis accelerometer can be fitted in order to measure motion sensing shock tilt Values can be configured using the application software Can be configured for motion sense time warning time and sensitivity Consult Scope for requirements Non Voltage Contacts 2 Configurable Message for each Contact Up to51 Chars Contact 1 Normally Open Contact Front pan...

Страница 10: ...1 Not recommended For Low power Battery Applications 2 When a Low Power event is detected the transmitter output power is automatically reduced in order to maintain maximise battery life 3 When the power can no longer support the Transmitter A power shut down message is transmitted Compliance R TTE directive 1999 5 EC EMC Directive 89 336 EEC EN 301 489 1 V1 4 1 Low Voltage Directive 73 23 EEC EN6...

Страница 11: ...I Compliant Copies of the Declaration of Conformity covering this product can be obtained from Scope FCC Part 15 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Scope s policy is on...

Отзывы: