scope DL4ACLUSA Скачать руководство пользователя страница 7

DigiLink  US  Mains Version

 

 

DIGUSAC 02/00 

 

 Issue 

6

 

Installation

 

 

The following procedure must be adhered to when installing the DigiLink paging system.  Ensure you have 
taken into consideration all of the above information before selecting the location for your transmitter.  If in doubt 
please consult your dealer. 
 

Remove the cover from the DigiLink transmitter unit by slackening the four Pozi head screws located at 
the top and bottom of the unit (see Diagram 1). 

 

Carefully lift off the cover and set aside. 

 

The transmitter should be fixed to an even wall surface using suitable screws fitted through the three 
holes provided in the chassis plate. Hold the chassis up to the chosen location and with the aid of a 
pencil mark the position of the mounting holes.   

 

Warning:

  

Do not use the chassis plate as a template for drilling the holes into the wall.  Hammer drills vibrating 

through the chassis may irreparably damage the quartz crystals on the printed circuit boards.   
 

Place the DigiLink transmitter over the mounting holes and secure the unit with suitable screws. Check 
that the chassis plate does not bend and that the screws do not snag or pinch any of the internal cables. 

 

Connect the antenna to the unit via the BNC connector located at the top of the housing.  If the antenna 
is an external antenna, or an antenna which is separate from the transmitter unit itself, ensure that the 
previous criteria covered under the section headed 

Location of the Hardware

, have been strictly 

adhered to (also see section headed

 

Other Antennas

). 

 

Connect the input cables to the zone terminals. Unless the unit has been specifically configured for 
voltage input, these should be simple “dry” (no voltage) contacts only (i.e. isolated switch or relay 
contacts).  
If configured for voltage input (5-18V dc), the jumper link beside the relevant terminal must be 
positioned nearest the “V” symbol marked on the circuit board (see diagram on page 9). 

If in doubt, check with your dealer before proceeding; incorrect

 

connection may cause 

permanent damage

 

If the unit is supplied with a sealed lead acid battery, plug together the two connector halves on the 
battery lead. The battery will now be in circuit and the unit will power up. 

 

Replace the cover and re-tighten the four retaining screws. 

 

Finally, after checking all connections, connect the mains cable supplied to a suitable isolated, fused 
spur or switched wall outlet. With mains power correctly applied, the red LED on the base of the unit  will 
light and Zone 8 will auto-trigger to indicate successful initialization. 

 
10  

The system is now active and will transmit the pre-programmed message for each of the zones when 
triggered. Repeat transmissions and other programmed parameters (e.g. battery low message) will be 
identified on the Configuration Data sheet(s) supplied with the system. 

 
 
 
 
 
 
 
 
 

Содержание DL4ACLUSA

Страница 1: ...lation User Manual Digilink MK2 Digilink MK2 Digilink MK2 Digilink MK2 Digilink MK2 Digilink Uhf Digilink Uhf Digilink Uhf Digilink Uhf Digilink Uhf ScopeCommunicationsUKLtd QuantumHouse Totnes DevonTQ95ALTel 441803860700 Fax 441803863716 Email sales scope uk comWebwww scope uk com ...

Страница 2: ...nse You should obtain the FCC Rules and Regulations Title 47 Part 80 to End including Parts 90 and 95 available from the US Gov Printing Office GPO Bookstore FCC Office or www fcc gov oet info rules Important Safety Information Scope products are designed to operate safely when installed and used according to general safety practices The following requirements should be observed at all times Do NO...

Страница 3: ...ired will vary between applications If portable equipment has been dropped or is worn by a person involved in an accident the unit should be tested again before re use It must be stressed that the physical range tests are essential and that any construction work or movement of plant or equipment could alter the signaling capability of the unit Radio equipment like any other requires servicing from...

Страница 4: ...ct indirect special incidental or consequential damages resulting from any defect in the product even if advised of the possibility of such damages The warranties and remedies set forth above are exclusive and in lieu of all others oral or written expressed or implied No Scope distributor dealer agent or employee is authorized to make any modification extension or addition to this warranty Some st...

Страница 5: ...non volatile memory Full details can be found in the SCPMON Monitor Program Help files Section 1 Installation The information contained in this Section is intended for use by authorized system installation engineers only Unqualified personnel should not undertake installation of this equipment under any circumstances whatsoever Location of the hardware Before locating the hardware in any given loc...

Страница 6: ...nce of the system will be affected by the type of material the unit is mounted on and its surroundings The following is a list of materials that this transmitter will be adversely affected by if mounted on or if mounted in close proximity to a Foil back wallboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect ra...

Страница 7: ...na or an antenna which is separate from the transmitter unit itself ensure that the previous criteria covered under the section headed Location of the Hardware have been strictly adhered to also see section headed Other Antennas 6 Connect the input cables to the zone terminals Unless the unit has been specifically configured for voltage input these should be simple dry no voltage contacts only i e...

Страница 8: ...fore removing cover The Transcoder PCB contains static sensitive components Care should be taken to avoid contact wherever possible and anti static precautions should be observed during installation Case Bottom Panel View Case Securing Screws slacken to remove cover Case Top Panel View Diagram 1 ...

Страница 9: ...8 on the main PCB see diagram page 8 2 Check the Configuration Data sheet supplied with the system to confirm the active trigger state of each input i e Normally Open Normally Closed or Change of State 3 If your system has been configured for Dry Contact operation ensure that no voltage is present on the input cables Also check that cable runs are not excessive preferably less than 10 meters and a...

Страница 10: ...DigiLink US Mains Version DIGUSAC 02 00 Issue 3 9 Transcoder PCB terminal connections ...

Страница 11: ...dealer subject to license conditions Specifically mounting height and Effective Radiated Power ERP Service Information If you experience a problem with your equipment please contact the distributor from whom it was purchased In any event ensure you have the systems details at hand for reference purposes Record your system details here for quick reference Date supplied____ ____ ____ Serial Number o...

Страница 12: ...Range 450 470 MHz Channel Spacing 25 KHz or 12 5KHz TX Baud Rate 512 or 1200 FCC Approval No JRNUSASERILINK General Ports 4 or 8 dry contact voltage inputs configurable Open Collector siren output 1A max COM1 serial port for programming function only Data POCSAG Numeric or Alphanumeric format Footprint mm 328 L x 190 W x 75 D max excluding aerial Scope s policy is one of continuous development and...

Отзывы: