Programmable UHF Radio Paging System

Models DL4EDC, DL8EDC

Scope Communications UK Ltd, Quantum House, Steamer Quay, Totnes, Devon TQ9 5AL

Tel: +44 1803 860700 Fax: +44 1803 8637

16 Email: [email protected] Web: www.scope-uk.com

DIGEDC5

Installation & User Manual

Digilink MK2

Digilink MK2

Digilink MK2

Digilink MK2

Digilink MK2

Digilink Uhf

Digilink Uhf

Digilink Uhf

Digilink Uhf

Digilink Uhf

Содержание Digilink MK2 DL4EDC

Страница 1: ...Quantum House Steamer Quay Totnes Devon TQ9 5AL Tel 441803860700Fax 441803863716Email sales scope uk comWeb www scope uk com DIGEDC5 Installation User Manual Digilink MK2 Digilink MK2 Digilink MK2 Digilink MK2 Digilink MK2 Digilink Uhf Digilink Uhf Digilink Uhf Digilink Uhf Digilink Uhf ...

Страница 2: ...se You should obtain the FCC Rules and Regulations Title 47 Part 80 to End including Parts 90 and 95 available from the US Gov Printing Office GPO Bookstore FCC Office or www fcc gov oet info rules Important Safety Information Scope products are designed to operate safely when installed and used according to general safety practices The following requirements should be observed at all times Do NOT...

Страница 3: ...ired will vary between applications If portable equipment has been dropped or is worn by a person involved in an accident the unit should be tested again before re use It must be stressed that the physical range tests are essential and that any construction work or movement of plant or equipment could alter the signaling capability of the unit Radio equipment like any other requires servicing from...

Страница 4: ...irect special incidental or consequential damages resulting from any defect in the product even if advised of the possibility of such damages The warranties and remedies set forth above are exclusive and in lieu of all others oral or written expressed or implied No Scope distributor dealer agent or employee is authorized to make any modification extension or addition to this warranty Some states d...

Страница 5: ...tem s secure non volatile memory Full details can be found in the SCPMON Monitor Program Help files Section 1 Installation The information contained in this Section is intended for use by authorized system installation engineers only Unqualified personnel should not undertake installation of this equipment under any circumstances whatsoever Location of the hardware Before locating the hardware in ...

Страница 6: ...ce of the system will be affected by the type of material the unit is mounted on and its surroundings The following is a list of materials that this transmitter will be adversely affected by if mounted on or if mounted in close proximity to a Foil back wallboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect rad...

Страница 7: ...ter unit itself ensure that the previous criteria covered under the section headed Location of the Hardware have been strictly adhered to also see section headed Other Antennas 6 Connect the input cables to the zone terminals Unless the unit has been specifically configured for voltage input these should be simple dry no voltage contacts only i e isolated switch or relay contacts If configured for...

Страница 8: ...Version DIGUSDCECO Issue 1 7 Installation The Transcoder PCB contains static sensitive components Care should be taken to avoid contact wherever possible and anti static precautions should be observed during installation ...

Страница 9: ... be noted that use of a siren will severely shorten the battery life Problems and Fault Finding 1 Check that the input cables are connected to the active zones For a 4 zone unit these are the lowermost terminal blocks on the main PCB see diagram page 9 2 Check the Configuration Data sheet supplied with the system to confirm the active trigger state of each input i e Normally Open Normally Closed o...

Страница 10: ...DigiLink US DC Version DIGUSDC 02 00 Issue 3 9 Transcoder PCB terminal connections ...

Страница 11: ...lt your dealer subject to license conditions Specifically mounting height and Effective Radiated Power ERP Service Information If you experience a problem with your equipment please contact the distributor from whom it was purchased In any event ensure you have the systems details at hand for reference purposes Record your system details here for quick reference Date supplied____ ____ ____ Serial ...

Страница 12: ...e 450 470 MHz Channel Spacing 25 KHz or 12 5KHz TX Baud Rate 512 or 1200 FCC Approval No JRNUSAECOLINK General Ports 4 or 8 dry contact voltage inputs configurable Open Collector siren output 1A max COM1 serial port for programming function only Footprint mm 184 L x 138 W x 45 D max excluding aerial Scope s policy is one of continuous development and specifications are subject to change without pr...