background image

ConneXions II V7 MAC Mains, Multi Port Version

 

 

CONV7MAC 05/98 

 

Issue 1 

9

 

Other Antennas

 

 
The range and performance of this equipment can be improved by the addition of more efficient 
antennas*. These can be installed either inside or outside the building and are connected to the transmitter 
with 50 OHM coaxial cable.  
 
Glass mount antenna (UHFGM): for installation on the inside of a suitable window. This can boost range, 
especially if it is required in one direction from the building. 
 
The centre fed half wave di-pole, measuring approximately 12 inches from tip to tip, will provide excellent 
all round local signalling. This can be mounted either inside or outside a building. Two versions are 
available:  
1) a light duty antenna suitable for sheltered environments/internal installation (LUHFDP). 
2)  a heavy duty stainless unit with optional mounting hardware for more arduous applications (UHFDP). 
 
Other antennas, including co-linears, are available for external applications. Consult our Sales Department 
for further details. 
 
Pre-terminated coaxial feeder cables are available for 5, 10 or 15 metre requirements.  

 
Note !

 High frequencies can equate to high power losses. Always use quality cable. RG58 is only 

acceptable on cable runs of up to 5 metres. We recommend RG213, or equivalent, on greater lengths. If in 
doubt consult our Technical Department. 
 

*subject to license conditions. Specifically, mounting height and Effective Radiated Power (ERP)

 

Service Information  

 
If you experience a problem with your equipment you must first telephone our service hotline, where we 
may request that you undertake a few simple checks. If  a problem still remains, we will arrange collection 
of your system by overnight carrier at our expense. Upon receipt, we will endeavour to service or replace 
the system within 24 working hours and return the same by overnight carrier. 
 
We suggest that you retain the packaging for your control equipment. Incorrectly packed goods returned 
for service are the responsibility of the customer. If we deem that new packaging is required before we can 
return the unit, a charge will be made. 
 
In the event that a pager requires service, return it directly to Scope in the pre-addressed service bag 
supplied with your system by registered post. Ensure that you carefully fill out the service form provided. 
Failure to complete this form in full will result in inevitable delays!    
 
Pagers returned with flat, incorrectly installed or leaking batteries will be charged for! 
 
Record your system details here for quick reference:- 
 
Date supplied____/____/____  Serial Number of the base console_________ 
 
Transmitter frequency ________MHz        Transmitter RA Type approval 13249 CONX7AC 
 
Number of pagers supplied with the system _______ 
 
System base ID number________________ 

Transmitter baud rate ______________ 

 
Serial input baud rate_____________ 
 

For information on individual pager types, refer to the appropriate pager manual

 

For information on use with the telephone I/F, refer to the separate Telephone Interface manual.

 

 
 
 
 
 
 

Содержание ConneXions II V7 MAC

Страница 1: ... Ltd The Scope Complex Wills Rd Totnes Devon TQ9 5XN Tel 44 1803 864569 Fax 44 1803 863716 CONV7MAC 1 Installation User Manual ConneXions ConneXions II RS232 Radio Paging System Multi Port Mains Version ConneXions ConneXions II V7 MAC ...

Страница 2: ...her equipment which is operated on a WT Act License Exempt basis The supply of this equipment is governed by our standard terms and conditions of sale which can be found on the reverse of all order acknowledgements proforma invoices delivery notes price lists and invoices Alternatively these can be provided on request Faxed proforma invoices and quotations refer to conditions available upon reques...

Страница 3: ...t under the applicable law will pass to the user who will absolve the manufacturer of any further responsibility for it s correct operation and use Liability Scope does not accept liability for any damage or injury howsoever caused as the result of misuse of this equipment It is the responsibility of the user to ensure that the equipment is operated in the manner for which it was intended and that...

Страница 4: ... is important to take into account the range of operation that you require to obtain from your system The standard transmitter can quite easily provide ranges of up to a mile or more and will provide excellent propagation on most industrial sites covering a considerable area with just a quarter wave antenna BNC terminated connected directly to the unit For coverage of very large sites or where exc...

Страница 5: ...ystem will be effected by the type of material the unit is mounted on and its surroundings The following is a list of materials that this transmitter will be adversely affected by if mounted on or if mounted in close proximity to a Foil back plasterboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect radio waves...

Страница 6: ...housing If the antenna is an external antenna or an antenna which is separate from the transmitter unit itself ensure that the previous criteria covered under the section headed Siting of the Hardware have been strictly adhered to also see section headed Other Antennas 6 It is important to note that due to the number of interfaces brought out to the 9 way D connector great care should be taken to ...

Страница 7: ... contact 7 If the unit is supplied with a sealed lead acid battery connect the battery leads to the terminals marked BATT and BATT on the power supply Positive Black White stripe Negative Black 8 Replace the cover and re tighten the four retaining screws 9 Finally after checking all connections insert the mains cable supplied into the IEC type connector located at the base of the unit and plug in ...

Страница 8: ...ConneXions II V7 MAC Mains Multi Port Version CONV7MAC 05 98 Issue 1 7 ...

Страница 9: ... in the mains plug The Scope mains input fuse on the integral power supply and the low voltage output fuse may also be checked by a suitably qualified technician 6 Check that the green LED lights for the duration of the transmission If not go back to the data cabling and re check the signal format 7 Check that the aerial is correctly installed Optional Dry Contacts This option must be specified at...

Страница 10: ...fective Radiated Power ERP Service Information If you experience a problem with your equipment you must first telephone our service hotline where we may request that you undertake a few simple checks If a problem still remains we will arrange collection of your system by overnight carrier at our expense Upon receipt we will endeavour to service or replace the system within 24 working hours and ret...

Страница 11: ...ent Channel better than 200nW 4 5 KHz deviation TX Baud Rate 512 or 1200 Type Approval ETS 300 224 MPT1383 Cert No 13249 Type Approval No 13249 CONX7AC EMC Approval EC Type Approved to ETS 300 682 Approval No 13331 General Ports RS232 serial on PL1 PL2 and PL3 Optional 10 way dry contact I F on PL1 Comms Baud Rate PL1 PL2 1200 Baud PL3 9600 Baud Footprint mm s328 L x 190 W x 75 D max dependent on ...

Страница 12: ... 1000 to 1 999 000 If for example a base address of 0100 000 is applied to a transcoder the first real pager number will 0100 008 followed by 0100 016 and so on Logical pager numbers are normally used on systems fitted with the telephone interface and those which are interfaced to personal computers The algorithm would perform the following function For example take the logical pager number of 123...

Страница 13: ...en LED lighting for the same period to show that data is being transmitted The time taken to transmit the message is dependent upon the pager baud rate For 512 baud this is approximately 4 seconds whilst at 1200 baud the time is approximately 2 seconds The unit can accept sequential data at 9600 baud which will be buffered and dealt with as soon as the preceding transmission has ended The RTS line...

Отзывы: