10
Operation
User Manual
SKOPE Centaur Series
3
Operation
Automatic Start-Up
Connect the cabinet to the mains power supply and check operation of the
refrigeration unit and electronic controller. Ensure the cabinet power switch
is turned on.
Power Switch
The cabinet is fitted with a power switch, usually located beside the
electronic controller. Depending on the model, it may be necessary to open
the unit front cover to access the switch.
Refrigeration
Unit
The compressor, and the condenser and evaporator fans should all operate
within two minutes from the time the cabinet is plugged in. This may be
verified by listening for compressor switch-on and checking for air
movement inside the cabinet. The compressor and condenser fan will switch
off when the cabinet internal air reaches a pre-set temperature.
Electronic
Controller
When the cabinet is connected to the power supply, the electronic controller
will display the current cabinet temperature. The compressor symbol
will
come on after a few minutes, indicating the compressor and condenser fan
is operating.
To ensure efficient operation, the electronic controller forces regular
defrosts. During the defrost cycle, the compressor and condenser fan switch
off and the evaporator fan stays on.
IMPORTANT
If the cabinet has been on its back, leave for 30 minutes
before running.