background image

Other:  

-Rain / Water proof 
-Built in strainer and Bypass Valve 
-Explosion proof permanent magnet motor 
-Thermal Overload protection 
 

Installation & Usage 

 

1) 

Tightly screw in suction pipe or dip tube (not supplied) into the 1” inlet using teflon 
tape. Your inlet tube or dip tube should terminate ~3” from the bottom of the drum or 
container.  

2)  Securely attach the 4 meter discharge hose (supplied) to the outlet. Use Teflon 

tape. 

3)  Connect your 12V power supply by removing the electrical junction box cover and 

connecting you power leads (Black -ve, Red +ve). Using an M20 (not supplied) 
cable gland seal the power cables as they leave the rear of the pump. 

4)  Pump body should be earthed as per the instructions on the pump label.  
5)  The pump is turned On or OFF with the Upper and Lower levers. Move the Upper 

Lever to ON. 

6)  Keep the nozzle in contact with the drum being filled.  

 

Warning:

  

 

1)  The drum or container being filled should be earthed to prevent static discharge and 

possible fire or explosion. The discharge hose is not conductive and does not 
provide an earth. 

2)  Do not install additional foot valves or check valves that do not have a pressure 

relief valve. 

 

Trouble Shooting 

 
Q) The pump is working but is not delivering appropriate flow rate or flow rate is 
decreasing. 
A) Possible hose or filter blockage or air leaks. Check all hoses and connections. Also 
check pump positioning, clean pump and check vanes are sliding easily. 
 
Q) Pump fails to prime. 
A) Check for air leaks in suction tube. Check bypass valve for grit or dirt. 
 
Q) Motor hums or fails to start. 
A) Pump motor may be bound. Remove cover and check rotor and vanes for dirt and 
make sure movement is free. 
 

Содержание SPEP12V75

Страница 1: ...st No Part Name QTY No Part Name QTY 1 Screw M8 16 2 14 Ring 1 2 Nozzle Holder 1 15 Cover 1 3 Motor 1 16 Screw M6 20 8 4 Pump Body 1 17 Inlet Joint 1 5 Bypass Valve 1 18 Filter 1 6 Spring 1 19 Gasket 1 7 O ring 26 5 2 65 1 20 Oil Pipe 8 Cover 1 21 Screw M5 12 4 9 Seals Assy 1 22 Cover 1 10 End Ring 9 1 23 O ring 1 11 Key 1 24 Upper LeverⅠ 1 12 Rotor 1 25 Upper Lever 2 1 ...

Страница 2: ...Exploded Pump View Features Voltage 12V Power 185 Watts Duty Cycle 30 Minutes Flow Rate 20 75LPM Operating Pressure 0 14MPA Current Draw 15 A Inlet Outlet 1 BSP Drum Fitting 2 BSP Hose length 4 meters ...

Страница 3: ... turned On or OFF with the Upper and Lower levers Move the Upper Lever to ON 6 Keep the nozzle in contact with the drum being filled Warning 1 The drum or container being filled should be earthed to prevent static discharge and possible fire or explosion The discharge hose is not conductive and does not provide an earth 2 Do not install additional foot valves or check valves that do not have a pre...

Страница 4: ...uding temperature pressure and viscosity If the accuracy of the flow meter is compromised then a calibration should be performed Calibrating flow meters is a normal part of their maintenance and is not an indication of a fault with the unit Calibration procedure 1 Unscrew the brass calibration plug shown in diagram 1 2 Purge the system pump piping meter of air 3 Stop the flow by shutting off the n...

Страница 5: ...dy and at the same time pulling it back towards the inlet in order to remove the O ring pos 17 from its seal at the outlet 5 To check the inside of the measuring chamber pos 27 remove the O ring pos 17 and divide the two half chambers containing the nutating disks 6 To reassemble the chamber reverse the procedure Be careful to verify the disk rotates freely in the chamber Install the gaskets prope...

Страница 6: ......

Отзывы: