WARNING: Read carefully and understand all
INSTRUCTIONS before operating. Failure to follow the safety
rules and other basic safety precautions may result in serious
personal injury.
A. MACHINE DESCRIPTION
PUMP:
Self-priming, volumetric, diaphragm pump, equipped with internal by-pass valve.
MOTOR:
Asynchronous motor, single-phase, 2 pole, closed type (protection class IP55 in conformance with
EN 60034-5-86 regulations) self-ventilated.
B. TECHNICAL DATA
B1. ELECTRICAL SPECIFICATIONS
PUMP MODEL
ELECTRICAL POWER
Flow Rate
POWER
Connection
Current
Voltage(V)
Frequency
Nominal(*)
(Watt)
Inlet/Outlet
SP12VADEF
DC
12
/
25LPM/6.6GPM
180
3/4”
SP24VADEF
DC
24
/
25LPM/6.6GPM
180
3/4”
C. OPERATING CONDITIONS
C1. ENVIRONMENTAL CONDITIONS
TEMPERATURE
: Min. -10oC
(
1
4℉)
/ Max. +60oC(14
0℉)
RELATIVE HUMIDITY
: Max. 90%
ATTENTION!
The temperature limits should be adhered to, to avoid damage to the pump.
C2. ELECTRICAL POWER SUPPLY
1. During installation and maintenance, make sure that the electric supply lines are not live.
2. Always turn off the switch before supplying electrical power.
3. Check the correct rotation direction of the DC pump. If it is inverted, check the polarity of the connection
cable.
a) RED cable: positive pole (+)
b) BLACK cable: negative pole (-)
ATTENTION!
Power from lines with values outside the indicated limits can damage the electrical components.
C3. WORKING CYCLE
1. Extreme operating conditions with working cycles longer than 30 minutes can cause the motor temperature
to rise, thus damaging the motor.
2. Each 30-minute working cycle should always be followed by a 30-minute power-off cooling phase.
3. MAXIMUM BY-PASS TIME: 3 MINUTES.