background image

Copyright (c) Scintex    www.scintex.com.au    [email protected] 

Page 1 

 

 

 

www.scintex.com.au |    [email protected] 

 
 

Model: BD150 

 

Scintex Biodiesel Processor

 

Assembly Instructions 

 

IMPORTANT

The process of making Biodiesel can release volatile gases (Methanol) from the tops of the 
vessels. The installed position of your BD150 relative to ignition sources and existing 
household electrical connections should be carefully considered. 

Your BD150 kit MUST be installed on firm flat ground.   

The BD150 should be kept in a location protected from the elements. Electrical components 
are not recommended for outside use. 

The metal frame of the kit can contain sharp edges and residual drilling swarf, SCINTEX 
promotes the use of gloves at all stages of frame assembly.

Содержание BD150

Страница 1: ...sels The installed position of your BD150 relative to ignition sources and existing household electrical connections should be carefully considered Your BD150 kit MUST be installed on firm flat ground...

Страница 2: ...as been labeled in a method designed to make assembly straight forward Steel should be arranged such that labels align AA BB CC etc See image 1 2 Bolts should be left finger tight until vessels are hu...

Страница 3: ...talled to mount correctly Discard the bolts provided with the vessel as these will not be the correct length the spring washers should be retained and reused See image 3 Once vessels have been hung al...

Страница 4: ...Copyright c Scintex www scintex com au sales scintex com au Page 4 Image 4 Image 5...

Страница 5: ...their mounting locations are as follows Remember to thread tape all threaded fittings to ensure they won t leak 2 Tank Fitting bottom of 200L vessel See Image 6 3 4 Tank Fitting Top of 200L vessel Se...

Страница 6: ...Copyright c Scintex www scintex com au sales scintex com au Page 6 Image 7 Image 8...

Страница 7: ...Box Screw the immersion heater into the 2 tank fitting at the bottom of the 200L cone bottom tank See Image 10 Note You may need to remove the tank fitting to create room for the immersion element to...

Страница 8: ...sales scintex com au Page 8 Image 11 STEP 6 Fitting Thermocouple The thermocouple has a bayonet style fitting Screw the bayonet into the 3 4 tank fitting half way up the 200L tank See Image 12 Then c...

Страница 9: ...ecommended all bolts are checked for tightness on a regular basis In some circumstances a small amount of lock tight may be required to ensure maintain a firm mounting STEP 8 Install Remaining Fitting...

Страница 10: ...Copyright c Scintex www scintex com au sales scintex com au Page 10 Image 14 Image 15...

Страница 11: ...Pump suction to lower manifold 1G Hose 3 4 2300mm Filter outlet bottom return to 200L 1D Hose 3 4 2000mm Lower manifold fill vessel hose 1E Hose 3 4 500mm Pump discharge to filter housing clamps 1F H...

Страница 12: ...Copyright c Scintex www scintex com au sales scintex com au Page 12 Diagram 1 Schematic of hoses and kit components...