background image

7

6.2 Mode B

When the instrument is turned ON and values for speed 

and time are erased to zero, users can set. The upper speed 

limit that has been set is taken over from operating mode 

A and cannot be modified. After the power has been turned 

OFF, the instrument will no longer automatically start up in 

operating Mode B by itself.

After turning ON the instrument and selected run mode, the 

following process will be shown on the display.

• The left LCD displays 

SAF

 and the right displays the

upper speed limit( rpm

which cannot be changed.

Figure 7

• The  LCD  displays  run  modes 

StA

  for  about  2

seconds.

Figure 8

• The set speed value is shown in the left display, and the set

time value is shown in the right display. Then set the motor

rotary speed and time.

Figure 9

Figure 10

•  After pressing the speed knob or time knob, the instrument

begins to run at the set speed. The actual speed and time

remaining are shown in the LCD. If the remaining has

reached zero, the shaker stops its motion.

Figure 11

Note:

 The set values can be varied during shaking.

Shaking can be stopped by pressing the left or 

right knob.

6.3 Switching the mode

Switch the operating mode as follows:

• Turn OFF the instrument with the mains switch.

• Hold down both knobs and turn ON the instrument with

Содержание SCI-L180-Pro

Страница 1: ...Orbital Digital shaker 7 5Kg Linear Digital shaker 2 5Kg Orbital Digital shaker 2 5Kg SCI L330 Pro SCI O330 Pro SCI L180 Pro SCI O180 Pro Please read the User Manual and the related Video of this inst...

Страница 2: ...4 Trial Run 3 5 Control and Set 4 5 1 Control 4 5 2 Set 5 5 2 1 Set Time 5 5 2 2 Setting Speed 5 6 Operating Modes 6 6 1 Mode A 6 6 2 Mode B 7 6 3 Switching the Mode 7 6 4 Switch the shaking directio...

Страница 3: ...oblem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty You have purchased a Scilogex instrument This instrument is warranted to be free...

Страница 4: ...the shaking table for medium splashing out of liquid when setting the motor speed Reduce the motor speed if the instrument is not running smoothly Accessories must be securely attached to the instrum...

Страница 5: ...r for technical support Note If there is any apparent damage to the system please do not plug it into the power line 3 2 Listing of Items The packing includes the following items Items Qty Main unit 1...

Страница 6: ...wnward with the wrench until the instrument is standing securely on the surface Figure 1 5 Control and Set 5 1 Control Shaking table Time knob LCD time LCD speed Figure 2 Items Descriptions Speed knob...

Страница 7: ...ion If continuous mode is selected the shake can continue its shaking function for any amount of time with the previously set speed If timed mode is selected the shaker can run in the set time After t...

Страница 8: ...ssing the speed knob and turning at the same time Figure 3 The LCD displays run modes StA A or B for about 2 seconds Figure 4 The set or stored speed value is shown in the left display and the set or...

Страница 9: ...changed Figure 7 The LCD displays run modes StA for about 2 seconds Figure 8 The set speed value is shown in the left display and the set time value is shown in the right display Then set the motor ro...

Страница 10: ...er one or multiple shaking vessels are placed 8 Faults When switched ON the instrument doesn t work Check whether the power cable fitted well Check whether the fuse is broken The speed cannot reach se...

Страница 11: ...supplier Before using another than the recommended method for cleaning or decontamination the user must ascertain that this method does not destroy the instrument Wear the proper protective gloves du...

Страница 12: ...ing output W 15 Permissible ON time 100 Speed range rpm 100 350 SK L330 Pro 100 500 SK O330 Pro 100 350 SK L180 Pro 100 800 SK O180 Pro Speed display LCD Timer Yes Timer display LCD Time setting range...

Страница 13: ...Roller Attachment 18900041 SK330 4 SK330 4 Dish Attachment with slip resistant foil 18900028 SK 330 2 SK 330 2 Fixing Clip Attachment 18900036 Bars for SK330 1 Universal Attachment black 18900025 SK 1...

Страница 14: ...lask Volume 50 ml 18900031 SK330 2 3 Fixing Clips for Flask Volume 100 ml 18900032 SK330 2 4 Fixing Clips for F l a s k Vo l u m e 200 250 ml 18900033 SK330 2 5 Fixing Clips for Flask Volume 500 ml 18...

Отзывы: