background image

USER MANUAL 

 

 

Make  sure  to  prepare  necessary  safety  measures  before  using  samples  that  are  toxic,  radioactive  or 

contaminated with pathogenic micro-organisms at your own responsibility. 

 

If the instrument, rotor and/or accessories that has been contaminated by solutions with toxic, radioactive 

or pathogenic materials, clean it according to the decontamination procedure that you are specified. 

 

If you require services at site, please sterilize and decontaminate it in advance, and then notice the service 

center involved in the details of the particular materials.   

 

Do  not  handle  the  power  cord  or  turn  on  or  off  the  POWER  switch  with  wet  hands  to  void  electrical 

shocks. 

 

For safety purposes, do not enter within 30cm around this centrifuge while it is in operation. 

 

While the rotor is rotating, never forcedly release the door lock. 

 

Unauthorized  repairs,  disassembly,  and  other  services  to  the  centrifuge  except  by  our  service  center  are 

strictly prohibited. 

 

 

 

  CAUTION 

 

This centrifuge must be located on one firm and level table. 

 

Make sure the centrifuge is horizontal before running. 

 

Make sure the angle between the door and cover is greater than 70 degrees when open the door. 

 

Be careful not put your fingers or hands between the door and cover when the door off. 

 

Do not move or relocate this centrifuge while it is running. 

 

If  fluid  spills  in  the  rotor  chamber,  please  promptly  clean  and  dry  with  a  dry  cloth  to  avoid  sample 

contamination.   

 

Ensure to remove any objects and fragments of the tubes dropped inside the rotor chamber before running 

this centrifuge. 

 

Cautions on rotors 

(1)  Always  check  for  corrosion  and  damages  on  the  rotor  surface  before  using  it.  Do  not  use  the  rotor  if  an 

abnormality is found. 

(2) Do not  set  the  centrifuge  speed  beyond the allowable minimum  speed of the rotor  kits (rotor or  adapters). 

Make sure to run it below the allowable minimum speed.

 

 

(3) Do not exceed the allowable imbalance. 

(4) Use the rotor and tubes within their actual capacities. 

(5) If the rotor is attached with a lid, ensure it is tightened before operation.

 

 

 

If  any  abnormal  condition  occurs  during  operation,  please  stop  it  immediately  and  contact  our  service 

center. Notify the service center is a warning code if displayed.   

 

Vibrations are likely to damage the centrifuge, contact our service center if abnormality observed. 

 

Содержание DM0636

Страница 1: ...DM0636 Multi purpose Centrifuge Before using centrifuge please carefully read this user manual for its efficient operation and safety...

Страница 2: ...ect the rotor 8 7 5 Symmetrically load centrifuge tubes in rotor 8 8 Operation 8 8 1 Normal Operation 8 8 2 RCF Operation 12 8 3 Pulse Operation 12 9 Maintenance 12 9 1 Cleaning 12 9 2 Consumables 13...

Страница 3: ...USER MANUAL 2...

Страница 4: ......

Страница 5: ...y be reproduced or transmitted without prior written permission of original manufacture We can not be responsible to inform at real time if the outline and specifications of centrifuge is subject to c...

Страница 6: ...death CAUTION Possible damage to instrument Caution notes indicate any condition or practice which if not strictly observed or remedied could result in damage or destruction of the instrument NOTE Not...

Страница 7: ...orizontal before running Make sure the angle between the door and cover is greater than 70 degrees when open the door Be careful not put your fingers or hands between the door and cover when the door...

Страница 8: ...emperature detector Imbalance protection Automatic internal diagnosis Power requirements Single phase 220V 240V 50Hz 60Hz 8A 110V 120V 50Hz 60Hz 12A Dimensions mm L 280 W 364 H 266 Weight 30kg Additio...

Страница 9: ...ich case the user will be required to correct the interference 3 Required Operational Condition 3 1 Basic operational Conditions 1 Power Single phase 220V 240V 50Hz 60Hz 8A Single phase 110V 120V 50Hz...

Страница 10: ...at least 30cm behind it to guarantee the cooling efficiency 4 Keep away from heat or water to avoid sample temperature issues or centrifuge failures 4 2 Connection of the power cord and grounding WAR...

Страница 11: ...Open lock key Press the key to open the door The key is not available when the centrifuge is running 3 Start Stop key Press the key to start running The centrifuge will brake to stop running if press...

Страница 12: ...is 9 memory program is 7 When speed symbol is rotating indicating the centrifuge is running the rotation is faster the speed is higher Temperature only displays the temperature of chamber and can not...

Страница 13: ...erwise the rotor may be moved off while rotating and cause damage of the centrifuge and rotor Firmly tighten the rotor door with rotor 8 Operation CAUTION Do not push or lean against the centrifuge wh...

Страница 14: ...00rpm Running time 30 minutes The door lock is released 8 1 1 Load and replace the rotor Figure 8 2 Load the rotor CAUTION Attach the rotor to the rotor shaft Ensure the rotor is in position and conne...

Страница 15: ...peed symbol will flash the speed value The minimum speed value you can set 300rpm the minimum increment is 100rpm Rotate parameter key clockwise to increase speed value rotate the parameter key anti c...

Страница 16: ...normal operation mode and run according to the new value If the set time value has been modified the operation time is not affected and will continue 3 Warning display If an error occurs during the o...

Страница 17: ...the power switch and load the rotor to the shaft tighten the rotor lid and make sure it is in secured position and then close the door 2 The centrifuge gets into preparation mode and displays last ru...

Страница 18: ...mple leaks in the rotor rinse the rotor with water Apply a thin coat of silicon grease to the rotor when it is completely dry The rotor should be regular maintenance recommend to cleaning it each 3 mo...

Страница 19: ...n the table firmly 2 Check if the centrifuge grounded properly Use multi meter to check if is short circuit between the power cord grounding pin and the motor shaft If yes indicating grounded properly...

Страница 20: ...llowable imbalance is exceeded some wrong in the drive system Balance the sample checked by professional person E 10 86 Read the service manual Contact with service center Table 10 1 Possible problems...

Страница 21: ...eed the allowable maximum speed of rotor tube and adapters etc be care that the allowable maximum speed of some adapters are lower than the rotor s maximum speed 11 1 The rotor instructions 11 1 1 Rot...

Страница 22: ...50mlV 4 A50VP100 4000 15 9 2840 15mlV 8 A15VP100 4000 15 1 2700 3 10ml 8 A10P100 4000 14 7 2630 9 S2 MP dimension mm MTP 128 85 6 15 4000 12 1 2160 Cell culture 128 85 6 21 4000 12 1 2160 DWP 128 85 6...

Страница 23: ...5 Bio safe seal ring The rotor is sealed by bio safe structures achieved using three high temperature rubber seal rings The seal rings may fall off or aging after several autoclaving need to be repla...

Страница 24: ...ove screw nuts and inner covers to prevent from deformation or rupture 3 Wait until the sterilizing chamber cools down to the room temperature before the tubes are removed 11 2 4 Condition and life ex...

Страница 25: ...otor kits with cover fixing clips and O ring 6000rpm PCR8 12 used with D1536 D1536R 19400002 AS6 50V Rotor kits with cover fixing clips and O ring 6000rpm 50mlV 6 used with D1536 D1536R 19400002 A30 1...

Страница 26: ...the following conditions even if within the guarantee period expires 1 Failures caused by incorrect installation 2 Failures caused by rough or improper handling 3 Failures caused by conveyance or rel...

Страница 27: ...USER MANUAL 22 SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 United States Office 1 860 436 9221 Fax 1 860 436 9745 Sales service contact info scilogex com www scilogex com...

Отзывы: