User Manual
2 MHz Function Generator
SM5060-2
Страница 1: ...User Manual 2 MHz Function Generator SM5060 2 ...
Страница 2: ...instrument contains proprietary information no part of this manual may be photocopied reproduced or translated without any prior written consent Information in this manual supercede all corresponding previous released material Scientific continues to improve products and reserves rights to amend part or all of the specifications procedures equipment at any time without notice Rev 1 0 0717 2 SM5060...
Страница 3: ...General Information 10 Safety 10 Operating Conditions 10 First Time Operation 11 Function Selection 11 Frequency Adjustment 11 OutputAmplitude Signal Connection 11 Trigger Output 12 Sweep Facilities 12 Internal Sweep 12 FM Input 12 DC Offset 13 6 Maintenance 14 Power Line Fuse Replacement 14 7 Dispatch Procedure for Service 15 8 Warranty Conditions 16 3 SM5060 2 User Manual ...
Страница 4: ...nt and test applications Its low frequency ranges are particularly well suited for simulating mechanical and servo techniques Frequencies are read out on a with a maximum 16 2 dot matrix LCD display resolution of 1 mHz Additional quality features include the relatively low distortion factor constant amplitude flatness of the generated signals and throughout the entire frequency range of the instru...
Страница 5: ...o 100 kHz max 0 5 100 kHz to 0 2 MHz max 1 0 0 2 z to 2 MHz max 1 5 MH Square Wave Risetime Typ 40 ns Overshoot W 5 when output is terminated with 50 Triangular Non Linearity 1 up to 100 kHz Frequency Display Accuracy up to 2 Hz 1 3 digit 2Hz to 2MHz 0 01 1 digit Output short circuit proof Output voltage 10 Vpp into 50 max 20 Vpp open circuit W Attenuation Max 60 dB 2 steps 20 dB each Variable 0 t...
Страница 6: ...speed 20 ms to 4s Sweep Range approx 1 100 General information Display 16 2 dot matrix LCD display Supply 230 V 10 50 Hz Power consumption 22 VA approx Operating Conditions 0 C to 40 C RH 95 max 0 0 Dimensions mm W 196 H 80 D 262 mm Weight Approx 2 0 kg Accessories Manual 1 no BNC BNC 1 no Line Cord 1 no Values without tolerances are intended as guidelines and represent characteristics of the aver...
Страница 7: ...B FUNCTION Mode selection switch Triangle Sine Square DC VARIABLE Control to change the slope of ramp waveform pulse duty cycle of pulse waveform SYM PB switch for generating ramp pulse waveform whenTri Sq function is selected respectively RANGE Frequency range selection from 0 2 Hz to 2 MHz in 7 decade steps 7 Front Panel Controls 1 7 2 3 4 5 6 8 2 7 10 POWER ON OFF OUTPUT OFFSET 20dB 20dB SWEEP ...
Страница 8: ...ssed the output signal gets attenuated by 20 dB fixed attenuator OUTPUT BNC connector Short circuit proof signal output of the generator The output impedance is 50 and the max output W amplitude is 20 V o c or 10 V respectively when terminated with 50 pp pp W When pressed the output signal gets attenuated by 20 dB fixed 20 dB attenuator When both attenuator pushbuttons are activated a total attenu...
Страница 9: ... when terminated with 600 pp pp W FM IN Banana socket External input for FM TRIG Banana socket Trigger output 4 mm Banana socket Mains Mains input 230 V AC 50 Hz 10 Spare Fuse Spare fuse for mains is kept inside 17 18 19 20 21 19 21 O P 600 W TRIG OUT 17 20 18 FM IN GND SCIENTIFIC MES TECHNIK PVT LTD B 14 POLOGROUND INDL ESTATE INDORE 452 015 INDIA SM5060 2 Power 230V 50Hz 22VA approx Fuse 0 15 A ...
Страница 10: ...egated by the use of an extension cord without a protective conductor WARNING ANY INTERRUPTION OF THE PROTECTIVE CONDUCTOR INSIDE OR OUTSIDE THE INSTRUMENT OR DISCONNECTION OF THE PROTECTIVE EARTH TERMINAL IS LIKELY TO MAKE THE INSTRUMENT DANGEROUS INTENTIONAL INTERRUPTION IS PROHIBITED THE MAINS LINE PLUG SHOULD BE INSERTED BEFORE CONNECTIONS ARE MADE TO MEASURING CIRCUITS When removing the metal...
Страница 11: ...to knob scales this display has a much higher resolution and accuracy OutputAmplitude and Signal Connections Adaptation in decade steps to the desired amplitude range is performed by the use of two attenuators with 20 dB each which are activated by pushbuttons Including the continuously adjustable AMPLITUDE control the maximum attenuation amounts to 60 dB With the maximum amplitude of 10V the pp m...
Страница 12: ...gnal The trigger output is short circuit proof and can drive severalTTLinputs Sweep Facilities Internal Sweep The internal sweep facility of the allows checking of filters and SM5060 2 equipment in the frequency range from 0 2 Hz to 2 MHz Operation is very easy and is confined to the setting of sweep speed and sweep width Activation is by simply pressing the pushbutton and can be combined with all...
Страница 13: ...ge and has the same U value in all ranges This mode can be used in applications where the periodically required frequencies are to be set This will eliminate the repetitive setting of frequency from front panel via FREQUENCY set knob Instead set the frequency setting knob to min and fed the equivalent DC input from VCF EXT FM in at the rear panel the desired frequency will be available Using multi...
Страница 14: ... clean lint free cloth Under no circumstances the cleaning fluid should get into the instrument The use of cleaning agents can attack the plastic paint surfaces Power Line Fuse Replacement The power line fuse is located on rear panel on lower right side In case the instrument does not show any sign of working no LCD is lit or there is no display immediately switch OFF the mains power switch of the...
Страница 15: ...ll details of the fault noticed 1 After receipt of your communication our service department will advise you whether it is necessary to send the instrument back to us for repairs or the adjustment is possible in your premises 2 Dispatch the instrument only on the receipt of our advise securely packed in original packing duly insured and freight paid along with accessories and a copy of the faults ...
Страница 16: ...y to any defect failure or damage caused by accident negligence mis application alteration or attempt to repair service or modify in any way 3 This warranty does not include LCD fuses batteries or accessories This warranty is only valid with the original purchaser who must have properly registered the product within 15 days from date of purchase No other warranty is expressed or implied 4 When it ...