![ScienTECH Vector P 25 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/scientech/vector-p-25/vector-p-25_setup-and-operating-procedures_1217302003.webp)
3
V
ECTOR
™
P
YROELECTRIC
D
ETECTOR
S
PECIFICATIONS
:
Model
P 25
PHF 25
PHD 25
PHDX 25 PHDX25UV
SP 25
SPHF 25
SPHD 25
Aperture Diameter
25.4 mm
25.4 mm
25.4 mm
7mm
7mm
25.4 mm
25.4 mm
25.4 mm
Spectral Response
.193-10.6
µ
m
.4-2
µ
m
.193-2
µ
m
.193-10.6
µ
m
Maximum Average Power
Minimum Energy
Noise Equivalent Energy
4 µJ
Maximum Energy Density
Note 2
Note 3
Note 4
Note 2
Peak Power Density
100MW/cm
2
800MW/cm
2
400MW/cm
2
100MW/cm
2
Accuracy
5%
5%
8%^
8%^
8%^
5%
5%
8%^
Output Sensitivity
8 V/J
8 V/J
2 V/J
2 V/J
2 V/J
8 V/J
8 V/J
2 V/J
Maximum Repetition Rate
100 pps
400 pps
40 pps
40 pps
40 pps
100 pps
400 pps
40 pps
Maximum Pulse Duration
0.2 msec
0.045 msec
0.2 msec
0.2 msec
0.2 msec
0.2 msec
0.045 msec
0.2 msec
Dimensions D x L - inches
2.4 x 2.3
2.4 x 2.3
2.4 x 2.3
2.4 x 3.9
2.4 x 3.9
2.3x2.3x0.6 2.3x2.3x0.6 2.3x2.3x0.6
cm
6.1 x 5.8
6.1 x 5.8
6.1 x 5.8
6.1 x 9.9
6.1 x 9.9
5.8x5.8x1.4 5.8x5.8x1.4 5.8x5.8x1.4
Weight - pounds/kgs
0.9/1.4
0.9/1.4
0.9/1.4
1.1/0.5
1.1/0.5
0.3/0.14
0.3/0.14
0.3/0.14
Indicator Compatibility
H410, H410D, S310, S310D, D200PC, D200P
Model
P 50
PHF 50
PHD 50
PHDX 50 PHDX50UV
SP 50
SPHF 50
SPHD 50
Maximum Beam Diameter
50.8 mm
50.8 mm
50.8 mm
15 mm
15 mm
50.8 mm
50.8 mm
50.8 mm
Spectral Response
.193-10.6
µ
m
.4-2
µ
m
.193-2
µ
m
.193-10.6
µ
m
Maximum Average Power
Minimum Energy
Noise Equivalent Energy
Maximum Energy Density
Note 2
Note 3
Note 4
Note 2
Peak Power Density
100MW/cm
2
800MW/cm
2
400MW/cm
2
100MW/cm
2
Accuracy
5%
5%
8%^
8%^
8%^
5%
5%
8%^
Output Sensitivity
Maximum Repetition Rate
50 pps
400 pps
20 pps
20 pps
20 pps
50 pps
400 pps
20 pps
Maximum Pulse Duration
0.4 msec
0.045 msec
0.4 msec
0.4 msec
0.4 msec
0.4 msec
0.045 msec
0.4 msec
Dimensions D x L - inches
3.5 x 2.3
3.5 x 2.3
3.5 x 2.3
3.5 x 3.9
3.5 x 3.9
3x3x0.6
3x3x0.6
3x3x0.6
cm
8.8 x 5.8
8.8 x 5.8
8.8 x 5.8
8.8 x 9.9
8.8 x 9.9
7.6x7.6x1.5 7.6x7.6x1.5 7.6x7.6x1.5
Weight - pounds/kgs
1.5/0.68
1.5/0.68
1.5/0.68
1.7/0.77
1.7/0.77
0.4/0.18
0.4/0.18
0.4/0.18
Indicator Compatibility
H410, H410D, S310, S310D, D200PC, D200P
^Beam centered on absorber
Note 1:
Max J/cm2 =316 x (pulse width)1/2
Note 2: HD models
Max J/cm
2
= 4500 x (pulse width)
1/2
to a maximum of 1.4 J/cm
2
.
Maximum pulse width of the pyroelectric detector must be observed.
Note 3: HDX models
Max J/cm
2
= 36,000 x (pulse width)
1/2
to a maximum of 12.6 J/cm
2
.
Maximum pulse width of the pyroelectric detector must be observed.
Note 4: HDXUV models Max J/cm
2
= 18,000 x (pulse width)
1/2
to a maximum of 5.6 J/cm
2
.
Maximum pulse width of the pyroelectric detector must be observed.
5 W with full illumination of the detector
10 W with full illumination of the detector
.193-26
µ
m
.193-26
µ
m
.193-26
µ
m
.193-26
µ
m
7% of selected range
n/a
n/a
n/a
n/a
2 V/J
Note 1
Note 1
Note 1
Note 1
16 µJ
7% of selected range
CE
M
ARK
C
ERTIFICATION
:
All of the pyroelectric detectors listed in this manual have been certified for the European CE mark.
E
NVIRONMENTAL
R
EQUIREMENTS
:
This product is intended for indoor use at altitudes up to 2000 meters, Pollution Degree 2 in accordance with
IEC 664 and transient overvoltages according to Installation Categories (Overvoltage Categories) II. Note that
each of the above detectors will not pass the IEC 801 Publication, Part 3, Radiated Electromagnetic Field
Requirements. The system, meter and detector, is designed to measure radiation within the test's radiation band.
The detectors were held outside the radiated electromagnetic field during this test. It is up to the user to be
aware of RF fields present during measurements and their effects if any on those measurements.