A.2
SEL-387-0, -5, -6 Relay
Instruction Manual
Date Code 20170601
Firmware and Manual Versions
Firmware
Table A.1
Firmware Revision History—SEL-387-0, -5, -6 Relay
(Sheet 1 of 5)
Firmware Identification (FID) Number
Summary of Revisions
Manual
Date Code
SEL-387-0-R611-V0-Z004004-D20140124
SEL-387-5-R611-V0-Z004004-D20140124
SEL-387-6-R611-V0-Z004004-D20140124
➤
).
20170601
SEL-387-0-R611-V0-Z004004-D20140124
SEL-387-5-R611-V0-Z004004-D20140124
SEL-387-6-R611-V0-Z004004-D20140124
➤
).
20160122
SEL-387-0-R611-V0-Z004004-D20140124
SEL-387-5-R611-V0-Z004004-D20140124
SEL-387-6-R611-V0-Z004004-D20140124
➤
).
20150126
SEL-387-0-R611-V0-Z004004-D20140124
SEL-387-5-R611-V0-Z004004-D20140124
SEL-387-6-R611-V0-Z004004-D20140124
SEL-387-0
➤
Revised relay so that password characters are not echoed as they are
entered.
➤
Increased the maximum number of allowed password characters
from six to twelve.
SEL-387-5 and SEL-387-6
➤
Improved the accuracy of DNP Delay Measurement response. In
previous firmware, the Delay Measurement response could be
incorrect by as much as 150 ms, which, in applications where the
DNP master uses this function code to measure the communication
channel delay, could cause the master to set the wrong relay time.
➤
Revised relay so that password characters are not echoed as they are
entered.
➤
Increased the maximum number of allowed password characters
from six to twelve.
20140124
SEL-387-0-R610-V0-Z004004-D20100324
SEL-387-5-R610-V0-Z004004-D20100324
SEL-387-6-R610-V0-Z004004-D20100324
➤
).
20120127
SEL-387-0-R610-V0-Z004004-D20100324
SEL-387-5-R610-V0-Z004004-D20100324
SEL-387-6-R610-V0-Z004004-D20100324
➤
Corrected problem with incorrect assertion of Relay Word bit
COMFLG when receiving RTD temperature data from an
SEL-2600 RTD module.
20100324
SEL-387-0-R609-V0-Z004004-D20071025
SEL-387-5-R609-V0-Z004004-D20071025
SEL-387-6-R609-V0-Z004004-D20071025
Supports PROTO=DNP
SEL-387-5-R409-V0-Z102102-D20050614
SEL-387-6-R406-V0-Z103103-D20050614
Does Not Support PROTO=DNP
SEL-387-6-R304-V0-Z003003-D20041018
➤
).
20090730
SEL-387-0-R609-V0-Z004004-D20071025
SEL-387-5-R609-V0-Z004004-D20071025
SEL-387-6-R609-V0-Z004004-D20071025
Supports PROTO=DNP
SEL-387-5-R409-V0-Z102102-D20050614
SEL-387-6-R406-V0-Z103103-D20050614
Does Not Support PROTO=DNP
SEL-387-6-R304-V0-Z003003-D20041018
➤
).
20071220
SEL-387-0-R609-V0-Z004004-D20071025
SEL-387-5-R609-V0-Z004004-D20071025
SEL-387-6-R609-V0-Z004004-D20071025
➤
Modified A5C1 Fast Message header to properly indicate Delta CT
connections when Group Setting W
n
CT = D (Delta).
➤
Corrected CHSG Relay Word Bit so that it will maintain the correct
state through a relay setting group transition.
➤
Set the default event record length equal to relay LER setting.
20071025
Содержание SEL-387-0
Страница 6: ...This page intentionally left blank ...
Страница 12: ...This page intentionally left blank ...
Страница 50: ...This page intentionally left blank ...
Страница 200: ...This page intentionally left blank ...
Страница 248: ...This page intentionally left blank ...
Страница 380: ...This page intentionally left blank ...
Страница 422: ...This page intentionally left blank ...
Страница 440: ...This page intentionally left blank ...
Страница 458: ...This page intentionally left blank ...
Страница 516: ...This page intentionally left blank ...
Страница 540: ...This page intentionally left blank ...