Schweigen TSH-900 Скачать руководство пользователя страница 5

Page 5

2. 

Your Safety

Before Installation

1. 

We recommend this appliance be installed or repaired by an experienced Home Appliances 
technician. 

2. 

Please see our website 

www.schweigen.com.au

 for experienced installers.

3. 

It is dangerous to modify any part of this appliance. Modification of any kind, will immediately  
void the warranty.

4. 

The manufacturer declines all responsibility in case of failure to adopt proper safety measures.

5. 

Ensure that the location in which this appliance is installed, has good and permanent ventilation.

6. 

Please consult local laws and regulations and install in accordance.

7. 

Use an electrical connector with earth that is correct for your location.

8. 

Check that the voltage in your area corresponds to the appliance as indicated on the rating label.

9. 

This appliance must be connected to an electricity supply with a 

ground connection

.

10. 

Check that the installation and electrical connections are made by a qualified technician and that the 
indicated instructions and local regulations in force are met, using materials that are compliant with 
the applicable legislation.

11. 

The company will not be responsible for installations executed by non-qualified staff and 
installations that fail to heed the applicable legislation on electrical safety (with regard to both 
modes and materials).

12. 

The electrical technical data can be found inside the rangehood, after removing the grease filters.

13. 

The flexible power cable supplied is already connected internally and emerges from the rangehood 
near the air outlet tube.

14. Before installing the electrical connections, you should:

 

Verify that the indicated electrical data coincide with the voltage values and frequency  
of the electrical circuit in the house where the rangehood is to be installed;

 

Check that the premises has electrical protection against short circuits and electrocution,  
pursuant to the applicable legislation;

 

Always switch off the current using the double-pole switch before maintenance and turn  
the power on again for normal use only when the operation has been completed.

Содержание TSH-900

Страница 1: ...www schweigen com au RANGEHOOD INSTALLATION GUIDE TSH 900 TSH 900B Revision 1 07 09 22...

Страница 2: ...allation 12 Rangehood Size vs Cooktop Size 12 Mounting Instructions 13 Recommended Installation Height for Induction Cooktop 13 Mounting Points for Body 14 Installation Example 15 Ducting 16 Back Draf...

Страница 3: ...website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the environmen...

Страница 4: ...including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use of the ap...

Страница 5: ...a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will not be respons...

Страница 6: ...use always ensure that all controls are in the OFF position When frying with a gas flame take particular care not to allow the oil or grease in the pan to catch fire Flamb Electrical Cord Ensure the...

Страница 7: ...on Flue Piece 3 Main Flue 4 Main Power Cord 5 Single Outlet 150mm 6 Filters 7 Light NOTE Filter and light quantity may vary from model to model Important Electronics MUST be accessible for service and...

Страница 8: ...w speed setting Medium speed setting High speed setting Turn on off the lamp Speed Control This undermount is equipped with a 3 speed mechanical control Speed control usage suggestions Low speed for s...

Страница 9: ...liquid soap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the direction of the st...

Страница 10: ...can be washed by hand or in the dishwasher Washing by hand Immerse the filter in hot water and a suitable detergent and when clean rinse with plenty of hot water Dishwasher Put the filter in the dishw...

Страница 11: ...riod of time after being switched off 5 Cleaning Maintenance Replacing the Lights Step 2 Gently turn light bulb anti clockwise pull the light bulb down and remove it from the light holder Step 3 Inser...

Страница 12: ...oktop Size In addition to the size the height of the rangehood above the cooktop is important to obtain the best performance INADEQUATE Rangehood smaller than cooking zone ADEQUATE Rangehood same size...

Страница 13: ...oktop Schweigen recommends a height between 700 750mm Refer to page 20 for further information IMPORTANT If the user decides to install the rangehood at a distance of less than minimum height above th...

Страница 14: ...appliance on a secure surface Please ensure that the holes for the two primary mounting points are level before installation 1 Primary Mounting Points 2 Adjust to Level 3 Secondary Mounting Points DA...

Страница 15: ...dingly if necessary 2 Once level continue to secure the rangehood via the secondary mounting points 3 Step 2 Feed through and secure the ducting from the rangehood outlet 1 2 3 1 2 3 Installation Exam...

Страница 16: ...cure The ducting diameter MUST be 150mm The overall length of the ducting should not be greater than 4 metres Ducting Please DO NOT crush or kink the ducting 1 Crushed or kinked ducting creates sharp...

Страница 17: ...ranty issue Back Draft Fins Back Draft Fins open position Back Draft Fins ducting Allowance for Back Draft Fins Back Draft Base Adding Carbon Filters optional If you are using the appliance in the rec...

Страница 18: ...city Keep the curves or bends to a minimum If they do exist try to keep the angles as open as possible Straight ducting is the most effective installation Never fit reductions next to curves or bends...

Страница 19: ...diameter this will reduce airflow Maximum 4m of ducting and straight line installation for best result Faulty Installation It is not the responsibility of Schweigen to rectify any incorrect installati...

Страница 20: ...istance from cooktop to the rangehood Speed of food liquid heating Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility...

Страница 21: ...en Check lights Make sure they are not broken or faulty Please make sure there is no obstruction in ducting or back draft fins Check the outlet make sure it is not blocked and you have the correct dia...

Страница 22: ...Page 22 9 Specifications Technical Specifications Model TSH 900 TSH 900B Feeding Voltage 220 240V 50Hz Lamp Power LED W 2 x 3W 900 500 500 1080 263 263 3 80 Dimensions...

Страница 23: ...r purpose s prior to use In no event will Schweigen Home Appliances be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information from their website or the...

Страница 24: ...rive Dingley Village Victoria 3172 Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emers...

Отзывы: