background image

Page 8

4. Description

Filters

Lamp (For GU10 fittings, please twist to remove)

Male Plug (Main Power 240V) 
Used for silent and non silent models
Two 200mm Outlets

Speed Control

This rangehood is equipped with a 3 speed mechanical control. 

Speed control usage suggestions:

•  Low speed for simmering.
•  Medium speed for light cooking.
•  High speed for heavy frying or heavy cooking.

Main Rangehood

Wall Mounting Bracket for section 2

1

1

Extension Flue

2

2

Main Flue

3

3

For use with Isodrive motor system 

4

4

5

5

6

6

7

7

8

8

NOTE: 

Filter and light quantity may vary from model 

to model.

Содержание CL7272S

Страница 1: ...Revision V5 1 HOME APPLIANCES www schweigen com au RANGEHOOD INSTALLATION GUIDE CL7272S ...

Страница 2: ...__________ 10 Cleaning the Interior ________________________________________________________________________________________ 11 Cleaning the Exterior ________________________________________________________________________________________ 11 Replacing the Light Bulb ___________________________________________________________________ 13 7 Installation Mounting Laws and Regulations _________________...

Страница 3: ...l safety and the lasting value of your rangehood We trust that you will enjoy your new Schweigen rangehood Please always retain your proof of purchase to aid in any warranty queries If you are unable to locate your warranty card one is available to download from our website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environme...

Страница 4: ...s not intended for use by person s including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance it is not a toy 8 The air must not b...

Страница 5: ...de by a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will not be responsible for installations executed by non qualified staff and installations that fail to heed the applicable legislation on electrical safety with regard to both modes and materials 12 The electrica...

Страница 6: ...ned with soft cloth and non corrosive detergent Do not leave the rangehood wet after cleaning or use please keep rangehood dry IMPORTANT Never attempt to repair this appliance by yourself Always refer to a qualified Service Technician Always switch off the electricity and unplug the connection before conducting maintenance or cleaning Electrical Cord Ensure the supply cord is not exposed to heat c...

Страница 7: ...e oil could overheat and catch fire 2 Never flambé any foods beneath the rangehood The flames could cause a fire 3 Before carrying out any operation inside the rangehood unplug the appliance from the electrical mains 4 Respect the cleaning frequencies and intervals for changing the filters as otherwise the accumulated grease could cause a fire or damage the product 5 Changes made to the steel surf...

Страница 8: ...ood is equipped with a 3 speed mechanical control Speed control usage suggestions Low speed for simmering Medium speed for light cooking High speed for heavy frying or heavy cooking Main Rangehood Wall Mounting Bracket for section 2 1 1 Extension Flue 2 2 Main Flue 3 3 For use with Isodrive motor system 4 4 5 5 6 6 7 7 8 8 NOTE Filter and light quantity may vary from model to model ...

Страница 9: ...g Turn on off the lamp 1 2 3 Schweigen silent rangehoods are recognised for their silent operation Although this holds true for all of our rangehoods with external motors one must note that the rangehoods are silent when they are used for regular cooking on the lower fan setting Therefore you will only hear the movement of air ...

Страница 10: ...0 hours of use Disconnect the electrical connection before any maintenance or cleaning processes are carried out To remove the filter pull the clip gently down until it disengages To replace perform the same operation but in reverse making sure the back two tabs of the filter are lined up with the rangehood In ceiling mounted rangehoods the doors or glass must be opened before accessing the filter...

Страница 11: ...flammable and COULD EASILY CATCH FIRE The manufacturer is exonerated from all responsibility in the event of fire due to poor maintenance of the grease filters Cleaning the Interior Clean the interior of the rangehood with a damp cloth and a neutral detergent or denatured alcohol NOTE Do not use denatured alcohol on the exterior of the rangehood Do not clean the electric parts or the motor with li...

Страница 12: ... contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the direction of the stained surface with the cloth refer to figure on left Do not pour any liquid directly on to the rangehood The cloth must have no buttons zips or fasteners that could scratch the surface It is strictly forbidden to use ch...

Страница 13: ...ns of the light bulb with the larger holes inside the light holder Once the pins are in place turn clockwise to secure the light bulb Step 1 Remove the filters from the rangehood DANGER Always switch off and disconnect the power cord before replacing any light bulbs Failure to do so may cause serious injury Please be aware that the light bulb will retain heat for a short period of time after being...

Страница 14: ...plane Outdoor Alfresco Area Minimum height 800mm Maximum height 1200mm For indoor kitchen area The minimum safety installation distance between the top of a cooktop and the lowest part of the rangehood are as follows Minimum installation height for electric and gas cooktops is 650mm For rangehoods 90cm wide or larger Distances above 800mm can compromise the extraction performance For 60cm wide ran...

Страница 15: ...r before installing the rangehood Failure to do so may cause serious injury Primary mounting points Secondary mounting points See Mounting Laws and Regulations WARNING If the user decides to install the rangehood at a distance of less than minimum height above the cooking surface the company declines responsibility for damages suffered by the rangehood due to excess heat or damage to objects peopl...

Страница 16: ...p 2 Feed the aluminium flexi duct from the outlet block to the kitchen ceiling Attaching ducting using either zip tie or duct tape Step 3 Place flue covers on make sure the flue sits in the well Step 4 Attach inside flue cover to the wall mounting bracket The wall mounting bracket determines the height of the internal flue section IMPORTANT Please make sure that all plastic protection on the range...

Страница 17: ...to be kept taut at all times Please refer to the Isodrive motor installation guide for more details on flexi ducting with the silent system BBQ Installation When installing the rangehood over a BBQ please be aware that the lid will obstruct the rangehoods effectiveness to extract smoke steam and odours Where possible remove the lid of the BBQ unit when in use to allow for effective rangehood extra...

Страница 18: ... 1600 3200 motor Single or Twin system To remove the clip hold down 1 2 and 3 gently pull out to direction 4 NOTE DO NOT REMOVE the clip at the end of the white cord when installing an Isodrive 650 900 motor Single or Twin system 1 2 3 4 For technical support please contact 1300 829 066 IMPORTANT ...

Страница 19: ...ie Please DO NOT rip the ducting Connect flexi ducting to the outlet on rangehood using duct tape or cable tie Please DO NOT rip the ducting Powerpoint should be located in an accessible area 2 3 5 7 6 8 4 9 10 1 2 3 4 5 6 7 8 9 10 Refer A NOTE The Isodrive motor system does not include the roof seal kit cable tie duct tape or the support straps The weather shield is only available for the Isodriv...

Страница 20: ...duce vapours rapidly This prevents the filters from gradually warming up and increases the chance of condensation forming There are many variables that can contribute to the condensation problem associated with induction cooktops and rangehoods Some of these variables include but are not limited to The Country or State you live in example WA versus VIC and the variables in daily temperatures The p...

Страница 21: ...st be a constant flow of air into the cooking area to avoid the creation of a depression which can affect the rate of aspiration Follow the advice from the instructions for induction systems with regards to the condensation effect Suggested height for induction cooktop is approx 750mm above the cooking surface Each person s circumstances are different but the vast majority of induction cooktop own...

Страница 22: ...connected to grounded plug and turned on Check motor switch Please ensure that there is power to the rangehood and the rangehood is switched on Check lamp switch Lamp switch should be at on position Check metal filter Metal filter should be washed regularly see filter cleaning Check lamps Lamps should be firm Check outlet Outlet should be open Check lamps and fuse Make sure they are not broken or ...

Страница 23: ...er inside the rangehood Faulty Installation It is not the responsibility of Schweigen Home Appliances to rectify any incorrect installations A service call out fee will be charged for any Schweigen technician that attends a call whereby it s established that the fault is due to an incorrect installation or non manufacturing fault Should the appliance be installed in such a way that the service age...

Страница 24: ...Page 24 9 Specification 795 797 350 352 550 600 700 1200 120 1240 Inner Flue Cover Outer Flue Cover ...

Страница 25: ...d and motor have been installed as per the instruction guides in order for optimal performance Schweigen Home Appliances has presented this information in good faith to all their retailers and distributors to convey before any all purchase s Information is supplied upon the condition that the person s receiving the information will make their own determination as to its suitability for their purpo...

Страница 26: ...Page 26 Notes ...

Страница 27: ...Page 27 ...

Страница 28: ...HOME APPLIANCES Distributed by Unit 102 45 Gilby Road Mt Waverley 3149 Victoria 1300 881 693 EST www schweigen com au ...

Отзывы: