8.3  SAFETY        

 

Check periodically for leaks in the system, or immediately when you smell gas. 

In case a leak is detected, extinguish all open flames in the area. 

Never leak test while smoking. 

If you cannot repair a leak, turn off gas supply at the cylinder valve and contact your gas supplier 

      or a qualified, licensed gas technician. 

Do not alter or modify this heater in any way 

 
 

 

8.1 STORAGE 

 
 

When heater is not in use for a prolonged period of time, remove gas cylinder. 
 
Verify that the gas valve is fully and tightly closed. 
 
Do not store the gas cylinder indoors. 
 
Store gas cylinder in a well ventilated area. 
 
For more compact storage and to avoid damage, the reflector may be removed 

8.2 PREVENTATIVE CARE AND MAINTENANCE 

 

The burner area is likely to attract spiders, especially inside orifices. Once a year, the heater should be 
inspected for spider webs, insects, and debris around burners and orifices. Plugged injectors or orifices 
will obstruct the gas flow to the burner. This will result in burner malfunction or possible damage. 
 
 

Have heater inspected

 

if.….. 

you smell gas combined with yellow tipped flames on burner. 

heater does not provide expected heat capacity 

burner makes little popping sounds while operating, other than when shutting down after  

      being turned off. When heater is warming up or cooling down a pinging metallic noise is normal. 

Page 15 

Содержание 4001-J SERIES

Страница 1: ...er appliance If you smell Gas Extinguish any open flames Don t touch electrical switches Call your Gas supplier immediately FIELD CONVERTIBILITY The conversion shall be carried out in accordance with...

Страница 2: ...form without prior written consent from the manufacturer Unauthorized use or distribution of this publication is strictly prohibited Schwank InfraSave 5285 Bradco Boulevard Mississauga Ontario L4W 2A6...

Страница 3: ...EQUIREMENTS PROPANE 6 3 4 SPECIFICATIONS 4001 2 4401 2 PROPANE MODELS 6 4 MAIN COMPONENTS FOR ASSEMBLY 7 5 ASSEMBLY INSTRUCTIONS 8 5 1 CONNECTION AND TESTING 11 TOPIC PAGE NUMBER 6 SAFE LOCATION FOR H...

Страница 4: ...GP M40J CX 08A 4001 2 J 4N11 2 J Manual RD April 2006 R L 08A KH...

Страница 5: ...below the burner The gas supply is fed up through the inside of the pole using flexible gas hose These installation and operating instruc tions are intended only for the patio heater Series 4001 2 J...

Страница 6: ...ied and licensed technician or your gas supplier Only those parts recommended by the Manufacturer should be used Substitution will void the warranty Do not use the heater until all connections have be...

Страница 7: ...0 w c is required to maintain correct burner input The pressure regulator and hose assembly supplied with the appliance MUST be used Any replacement pressure regulator and hose must conform to standar...

Страница 8: ...401 2 J 44N1 2 J Main Burner Head assembly unit 34 housing and Base Post Support Brackets 3 each 46 gas supply line Aluminum Reflector 5 pc Sectional 4 ea M6 x 20mm Bolts for Burner Assembly Upper Pos...

Страница 9: ...s to base L brackets using four 8 x 3 4 bolts and nuts Note Bolt heads face the wheel Position wheel brackets with curve up Align pairs of holes in each end of L brackets to those in op posite sides o...

Страница 10: ...ing 1 2 pipe thread to flared fitting adapter Install 1 2 male pipe thread of 18 ft rubber gas hose into gas regulator inlet side Remove finger tight nut from 10 bolt extending from top side of base U...

Страница 11: ...semble the four outer reflector sections using 1 4 washers and wing nuts on only the outer studs Assemble the centre piece to the outer ring using wing nuts Secure reflector to burner with wing nuts 5...

Страница 12: ...ll If the leak cannot be repaired permanently close the cylinder valve completely and contact a qualified and licensed gas technician After successful leak test ensure that the burner assembly and all...

Страница 13: ...l heater on a levelled solid and stable surface Do not install in an explosive environment Keep away from areas where gas vapours are present or inflammable liquids are stored or used In case of stron...

Страница 14: ...wise TO TURN OFF 1 Turn the knob clockwise until it stops 2 Depress knob and turn fully clockwise to shut of the gas supply completely Warning A 5 minute complete shut off period is required before th...

Страница 15: ...sure is low or regulator is defective Replace empty LPG gas cylinder or defec tive regulator Check gas pressure NG Gas inlet hose is kinked or bent Spider or insect cocoon Check straighten out hose fo...

Страница 16: ...ylinder indoors Store gas cylinder in a well ventilated area For more compact storage and to avoid damage the reflector may be removed 8 2 PREVENTATIVE CARE AND MAINTENANCE The burner area is likely t...

Страница 17: ...rantydoes not cover heating products improperlyinstalled misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water excessive thermal shock impact abrasion norma...