Technical specifications

Battery

Alkali 2 x AA, 1.5 V

Battery life

Up to 4-5 years

Backlight

Green LED

Ambient temperature

0˚ to +40 ˚C

Battery monitoring

The sensor has a built-in monitoring circuit 

which detects a low or critical battery level.

Transmission frequency

868.42 MHz

Transmission range in normal buildings

Up to 30 m

Transmission power

Max. 1 mW

IP degree of protection

21

Dimensions

81 mm x 66 mm x 21 mm

Configuration Command Class

Functions

No. Configuration 

parameter

Standard 

setting

Area

Coding

1

Temperature Report 

threshold

0,5 °C

0.1 to 10 °C

2 bytes

1 = 0.1 °C

100 = 10.0 °C

2

Set-point display 

resolution

0,5 °C

From 0.1 to 10 ° C in 

steps of 0.1 ° C

2 bytes

1 = 0.1 °C

100 = 10.0 °C

3

Min. set-point and 

override limit

12 °C

Min. 0 ° C to max. 

setpoint/output

2 bytes

0 = 0 °C

40 = 40 °C

4

Max set-point and 

override limit

28 °C

Min. setpoint/output 

to max. 40 °C

6

Setpoint control 

function

Activated

Deactivated/activated 1 byte

0 = deactivated

1 = activated

7

Temporarily override 

scheduler

Activated

Deactivated/activated

8

Setpoint in

Thermostat_

Setpoint_Reports

Heating

Heating #1, 

cooling #1,

auto changeover

1 byte

1 = heating #1

2 = cooling #1

10 = auto

changeover

9

LED on time

100 ms

100 to 500 ms in 

steps of 100 ms

1 byte

1 = 100 ms

5 = 500 ms

5

LED Flash period

1 s

0 to 65,535 seconds

2 bytes

10

Number of LED

flashes (duration)

5

0 to 255 x flashes

1 byte

11

LED Color

Green

Green, red

1 byte

0x01 = green

0x02 = red

1. Raumtemperatursensor

Command Class

SENSOR_

MULTILEVEL

The room temperature is shown on the 

display as the icon   indicates. If inserted 

in the Z-Wave network the temperature 

is reported to the controller when the 

device is switched on as well as during 

changes in temperature, in which the 

configured limit is exceeded.

Display accuracy

0,1 °C

Sensor read

Every  5 minutes

Report send

When switching on

If you exceed the

reporting threshold

CONFIGURATION 

COMMAND CLASS

Default setting

Area

Report threshold

0,5 °C

0,1 to 10 °C

2. Rocker switch

Command Class

CENTRAL_SCENE

When clicking the LED button a 

CENTRAL_SCENE_NOTIFICATION is

sent to the controller.

Supported key

attributes

0x00/0x01/0x02

3. LED control

Command Class

INDICATOR

The controller can trigger and stop a 

flashing session on the LED button using 

the set display command. The frequency, 

flashing frequency and colour of the 

session are controlled by 4 configuration 

parameters.

Indicator Set

0xFF = start

LED flashing session
0x00 = stop

current session

CONFIGURATION 

COMMAND CLASS

Default setting

Area

LED on time

100 ms

100 to 500 ms in steps of 100 ms

LED Flash period

1 s

0 to 65535 seconds

Number of LED flashes 

(duration)

5

0 to 255 x flashing

LED colour

Green

Green, red

4. Change setpoint

Command Class

THERMOSTAT_

SETPOINT

The up and down arrow keys are used 

to select a new setpoint temperature. 

After selection of a setpoint this flashes 

for 5 seconds. Thereafter, the measured 

temperature is displayed again and the 

Z-Wave RS sends the selected tempera-

ture as THERMOSTAT_SETPOINT_

REPORT to the Z-Wave controller.

Indicator Set

0xFF = LED-

flashing session starts
0x00 = stop

current session

CONFIGURATION 

COMMAND CLASS

Default setting

Area

Setpoint control 

function

Activated

Deactivated/activated

Set-point display 

resolution

0,5 °C

From 0.1 to 10 °C in steps of 0.1 °C

Max set-point and 

override limit

28 °C

From min. setpoint/clip to max. 40 °C

Min. set-point and 

override limit

12 °C

From min. 0 °C to max. setpoint/clip

Setpoint in

Thermostat_

Setpoint_Reports

Heating #1

Heating #1,

cooling #1,

auto changeover

5. Scheduler override thermostat

Command Class

SCHEDULE

The up and down arrow keys are used to 

select the temporary override temperature.  

The selected value flashes on the display for 

5 seconds. Press the LED button before the 

5 seconds are over to select the number of 

hours for the override.  The selected number 

of hours flashes for 5 seconds.  Thereafter, 

the measured temperature is displayed again 

and the Z-Wave RS sends the selected tem-

perature and the number of hours as SCHE-

DULE_REPORT to the Z-Wave controller. 

CONFIGURATION 

COMMAND CLASS

Default setting

Area

Temporarily override 

scheduler

Activated

Deactivated/activated

Set-point display 

resolution

0,5 °C

From 0.1 to 10 °C in steps of  0.1 °C

Max set-point and 

override limit

28 °C

From min. setpoint/clip to max. 40 °C

Min. set-point and 

override limit

12 °C

From min. 0 °C to max. setpoint/clip

Z-Wave networks

Z-Wave RS can be installed and operated in any Z-Wave network with other Z-Wave certified devices 

from other manufacturers. Independently from respective manufacturers all permanently powered 

Z-Wave nodes function as Repeaters within a network 

Z-Wave best practice 

• After the successful „paste“ the controller must send a WAKE_UP_INTERVAL_SET command to 

  Z-Wave RS to specify where and when Z-Wave RS should communicate wirelessly. 

• After issuing the command WAKE_UP_INTERVAL_SET, the controller must assign return routes, so 

  that Z-Wave RS can reach its goal, i.e. the node ID given by the command WAKE_UP_INTERVAL_SET

•  The node ID given by the command WAKE_UP_INTERVAL_SET applies to a permanently switched-on 

  device that responds to commands sent from Z-Wave RS.  If the controller is turned off for long 

  periods, the batteries of the Z-Wave RS are used up too quickly.

•  Although Z-Wave RS responds to individual commands, multiple commands must always be used to 

  ensure the two year battery life.

 

Delete from Z-Wave  

•  Press „Exclusion/Remove“ on the Z-Wave controller.  

•  Keep the three buttons on the Z-Wave RS pressed for 5 seconds (up, down and LED buttons). 

•  Check the process status on the controller and  Z-Wave RS. 

Z-Wave wake up

A controller can only communicate with Z-Wave RS when the device is switched on. The intervals in 

which Z-Wave RS is turned on can be adjusted by means of the command class „switch on.“   The 

default setting for switching on is 60 minutes.  Z-Wave RS can be turned on manually by pressing one 

of three buttons and then stays on for 10 seconds. 

Resetting to factory default settings

1. Remove one of the batteries.

2. Hold the LED button for about five seconds when 

  reinserting the battery until the LED flashes red. 

  The Z-Wave RS is now reset to the factory default settings.