1 - SYMBOLS USED IN THE MANUAL

NOTE!

Tips 

for the user

ATTENTION!

Possible dangerous 

situation for the product and the environment

DANGER!

Serious danger for 

personal safety and life

2 - APPROPRIATE USE OF APPLIANCE

The SWG boiler has been built according to the current level of engineering and acknowledged 

technical safety rules. 

Nonetheless, if improperly used, dangers could arise for the safety and life of the user and 

other persons or damage to the equipment or other objects. 

The appliance is designed to work in heating systems, with hot water circulation, for the pro-

duction of domestic hot water.

Any other use is considered improper. 

The manufacturer will not be held liable for any damage resulting from improper use.

Use according to the intended purposes also includes strict compliance with the instructions 

in this manual.

The user must be instructed concerning the use and operation of the heating system, in particular: 

•  Deliver these instructions to the user, as well as other documents concerning the appliance 

inserted in the envelope inside the packaging. The user must keep this documentation safe 

for future consultation. 

•  Inform the user about the importance of the air vents and the flue gas exhaust system, high

-

lighting their essential features and the absolute prohibition of modifying them. 

•  Inform the user concerning controlling the system's water pressure as well as operations to 

restore it. 

•  Inform the user concerning correct temperature control, control units/thermostats and radiators 

for saving energy.

•  Remember that the system must receive regular maintenance at least once a year and com

-

bustion analysis must be performed every two years (as per national law).

•  Should the appliance be sold or transferred to a new owner or if you move and leave the 

appliance, always make sure that the instruction booklet accompanies it in order to be con-

sulted by the new owner and/or installer. 

The manufacturer will not be held liable in the event of damage to persons, animals or objects 

resulting from failure to comply with the instructions contained in this manual.

4 - INFORMATION PROvIDED TO THE USER 

  BY THE INSTALLATION/MAINTENANCE TECHNICIAN

3 - WATER TREATMENT

•  The hardness of the feed water conditions the frequency at which the domestic hot water 

exchanger must be cleaned.

•  If the water has a hardness greater than 15°f, we recommend using water softeners, chosen 

according to the characteristics of the water.

•  In order to improve scaling resistance, it is recommended to adjust the domestic hot water at 

a temperature very close to that actually used.

•  It is recommended to verify the cleanliness of the domestic hot water exchanger at the end 

of the first year, and then according to the level of scaling found; the period can be extended 

to two years.

Pay special attention when reading this manual to the parts marked by the symbols:  

Provisions for proper disposal of the product in accordance with Directive 2002/96/EC 

At the end of its life cycle the product must not be disposed of as urban waste. It can be taken to 

a special recycling centre managed by the local authorities, or to a dealer who offers this service.  

Separate disposal of a domestic appliance avoids possible negative consequences for the environment 

and human health deriving from inappropriate waste handling and allows the recovery of the materials 

of which it is made, in order to obtain significant energy and resource savings.

Содержание SWG

Страница 1: ...SWG ENGLISH uSER S OPERATION INSTRUCTION ...

Страница 2: ...ting safety of the appliance ATTENTION To tighten or loosen the screwed fittings use only appropriate fixed spanners Non compliant use and or inappropriate tools can cause damage e g water or gas leakage ATTENTION Indications for propane gas fired appliances Make sure that the gas tank has been deaerated before installing the appliance For state of the art tank venting contact the LPG supplier or ...

Страница 3: ...ar and com bustion analysis must be performed every two years as per national law Should the appliance be sold or transferred to a new owner or if you move and leave the appliance always make sure that the instruction booklet accompanies it in order to be con sulted by the new owner and or installer The manufacturer will not be held liable in the event of damage to persons animals or objects resul...

Страница 4: ...tion and heating temperature adjustment Positioning the knob in the field shown to the side indicates that the boiler is in Winter mode and adjusts the temperature of the heating circuit water The adjustment is between min 45 C and max 78 C C Domestic hot water temperature regulator Via this knob it is possible to ad just the domestic hot water inlet temperature Positioning the knob in the field i...

Страница 5: ...he symbol on the display display the error code when the boiler operation is block due to a permanent fault activating the symbol on the display Thermometer If on the display the symbol is lit up the temperature in dicated is that relating to the water for the heating circuit If on the display the symbol is lit up the temperature in dicated is that relating to the water for the domestic hot water ...

Страница 6: ...sition the two knobs as shown in the figure The antifreeze protection inter venes only if the boiler is powered electrically and if the gas valve is open If for some reason there is a power or gas failure the antifreeze protec tion described above is not active Heating discharge For operation in heating mode the knob B must be positioned in the field shown in the figure In correspondence of MIN th...

Страница 7: ...d flashing in place of the degrees centigrade for the error codes list see par 4 6 installation and maintenance instruction manual The user can intervene to restore proper operation only in the following cases System pressure too low How to elimi nate the fault Restore the correct pressure value by acting on the boiler filling valve for optimum operation the pres sure value should be within 0 8 an...

Страница 8: ...feriore 52 C 29012 Caorso PC Italy e mail info schusterboilers com www schusterboilers com The manufacturer declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Отзывы: