SWG
ENGLI
SH
uSER’S OPERATION INSTRuCTION
Страница 1: ...SWG ENGLISH uSER S OPERATION INSTRUCTION ...
Страница 2: ...ting safety of the appliance ATTENTION To tighten or loosen the screwed fittings use only appropriate fixed spanners Non compliant use and or inappropriate tools can cause damage e g water or gas leakage ATTENTION Indications for propane gas fired appliances Make sure that the gas tank has been deaerated before installing the appliance For state of the art tank venting contact the LPG supplier or ...
Страница 3: ...ar and com bustion analysis must be performed every two years as per national law Should the appliance be sold or transferred to a new owner or if you move and leave the appliance always make sure that the instruction booklet accompanies it in order to be con sulted by the new owner and or installer The manufacturer will not be held liable in the event of damage to persons animals or objects resul...
Страница 4: ...tion and heating temperature adjustment Positioning the knob in the field shown to the side indicates that the boiler is in Winter mode and adjusts the temperature of the heating circuit water The adjustment is between min 45 C and max 78 C C Domestic hot water temperature regulator Via this knob it is possible to ad just the domestic hot water inlet temperature Positioning the knob in the field i...
Страница 5: ...he symbol on the display display the error code when the boiler operation is block due to a permanent fault activating the symbol on the display Thermometer If on the display the symbol is lit up the temperature in dicated is that relating to the water for the heating circuit If on the display the symbol is lit up the temperature in dicated is that relating to the water for the domestic hot water ...
Страница 6: ...sition the two knobs as shown in the figure The antifreeze protection inter venes only if the boiler is powered electrically and if the gas valve is open If for some reason there is a power or gas failure the antifreeze protec tion described above is not active Heating discharge For operation in heating mode the knob B must be positioned in the field shown in the figure In correspondence of MIN th...
Страница 7: ...d flashing in place of the degrees centigrade for the error codes list see par 4 6 installation and maintenance instruction manual The user can intervene to restore proper operation only in the following cases System pressure too low How to elimi nate the fault Restore the correct pressure value by acting on the boiler filling valve for optimum operation the pres sure value should be within 0 8 an...
Страница 8: ...feriore 52 C 29012 Caorso PC Italy e mail info schusterboilers com www schusterboilers com The manufacturer declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...