10 Troubleshooting
10.1 The clamping area does not unlock
Possible cause
Remedial measures
Defective air connections
Check air supply
Pressure below minimum
Check operating pressure (min. 5 bar)
A component is broken (e.g. due to
overloading)
Replace the module or send it to SCHUNK for
repair
Excess tensile load on clamping pins
Reduce support weight
10.2 The clamping area does not unlock properly
Possible cause
Remedial measures
Pressure below minimum
Check operating pressure (min. 5 bar)
The module was not operated with oiled
compressed air
Install maintenance unit with oiler
Hose diameter below minimum
Required hose diameters, see chapter
"Securing and connecting"
The turbo connection is still pressurized
Ventilate the connection
10.3 The quick-change pallet system no longer opens quietly
Possible cause
Remedial measures
The clamping faces on the clamping slides
and on the clamping pin are dirty
Remove the clamping pin and clean the
clamping faces on the clamping slides and on
the clamping pin
10.4 If the clamping area does not unlock properly
Possible cause
Remedial measures
Clamping pallet is not flat
Depressurize media transfer units, bleed supply
to transfer units
Clamping pallet is not flat
Increase the force applied to the coupling
connection until the flat contact surface of the
module has been reached
Clamping pallet is not flat
Check installation position of coupling
elements