Troubleshooting
50
03.00|1152197 NSE3, NSE-T3 |en
Troubleshooting
The clamping area does not unlock
Possible cause
Remedial measures
Defective air connections
Check air supply
Pressure below minimum
Check operating pressure (min. 5 bar)
A component is broken (e.g. due to
overloading)
Replace the module or send it to SCHUNK for
repair
Excess tensile load on clamping pins
Reduce support weight
The clamping area does not unlock properly
Possible cause
Remedial measures
Pressure below minimum
Check operating pressure (min. 5 bar)
The module was not operated with oiled
compressed air
Install maintenance unit with oiler
Hose diameter below minimum
Required hose diameters, see chapter
"Securing and connecting"
The turbo connection is still pressurized
Ventilate the connection
The quick-change pallet system no longer opens quietly
Possible cause
Remedial measures
The clamping faces on the clamping slides
and on the clamping pin are dirty
Remove the clamping pin and clean the
clamping faces on the clamping slides and on
the clamping pin
If the clamping area does not unlock properly
Possible cause
Remedial measures
Clamping pallet is not flat
Depressurize media transfer units, bleed
supply to transfer units
Clamping pallet is not flat
Increase the force applied to the coupling
connection until the flat contact surface of the
module has been reached
Clamping pallet is not flat
Check installation position of coupling
elements
8
8.1
8.2
8.3
8.4
Содержание VERO-S NSE-T3 138
Страница 30: ...Assembly 30 03 00 1152197 NSE3 NSE T3 en...
Страница 33: ...Assembly 03 00 1152197 NSE3 NSE T3 en 33...
Страница 39: ...Assembly 03 00 1152197 NSE3 NSE T3 en 39 Usage arrangement of the different types of clamping pins...
Страница 55: ...Assembly Drawings 03 00 1152197 NSE3 NSE T3 en 55 Assembly Drawings NSE3 138 assembly 10 10 1...
Страница 56: ...Assembly Drawings 56 03 00 1152197 NSE3 NSE T3 en NSE T3 138 assembly 10 2...
Страница 57: ...Assembly Drawings 03 00 1152197 NSE3 NSE T3 en 57 Cone seal KVS3 138 10 3...