Observe the following when controlling:
Turbo function:
• The actuating pressure for the turbo function must not exceed
6 bar.
Clamping slide monitoring
• The max. pressure for clamping slide monitoring is 2 bar.
• Limit volumetric flow to 15 l/min.
• Pressure difference upon failure of a module min. 1 bar.
Air purge:
Connection via the bottom connection thread:
• Max. pressure 2 bar.
• Limit volumetric flow to 15 l/min.
• The air purge must be switched off before the modules are
locked, as otherwise an air cushion may form.
Blow-out air:
Connection via the bottom connection thread: M7:
• Max. pressure 6 bar, max. 3 bar directly during loading.
• The blow-out air must be switched off before the modules are
locked, as otherwise an air cushion may form.
Contact monitoring / automatic cleaning of the contact surfaces
Every contact surface of the quick-change pallet module has a
bore hole that can be used to control the pallet using dynamic
pressure measurement. Due to the decreasing gap between the
quick-change pallet system and the pallet during the approach,
there is an additional cleaning effect for the contact surface of the
quick-change pallet module. The following ranges can be
controlled via the connections 5, 6, 11 shown in the following
illustration:
Содержание VERO-S NSE-A3 138
Страница 26: ...Assembly 26 02 00 1376941_NSE A3 en ...
Страница 29: ...Assembly 02 00 1376941_NSE A3 en 29 Usage arrangement of the different types of clamping pins ...
Страница 46: ...Assembly Drawings 46 02 00 1376941_NSE A3 en Assembly Drawings Assembly 10 10 1 ...
Страница 47: ...Assembly Drawings 02 00 1376941_NSE A3 en 47 Cone seal KVS3 138 10 2 ...