Maintenance and care
26
05.00|0489065 KSH plus, KSH-LH plus, KSH-F plus |en
Maintenance and care
To ensure the clamping block operates perfectly, the following
instructions are to be observed:
• Make sure the borehole for coolant drainage
is clear at all times!
• Lubricate the guides on the two front or the two side
lubricating nipples with LINOMAX 200 depending on load, but
at least once per month or every 10,000 clamping operations.
Make sure the chuck jaws are in the open position.
• Upgrade the base jaws and the chuck piston at least every
three months or more often if necessary (see chapter
"Disassembling and assembling the clamping force block", point
1–8
). Clean the housing, base jaws and chuck
piston, and lubricate all the guides (housing, base jaws, chuck
piston) with LINOMAX 200. Reassemble everything and
relubricate the two front or two side lubricating nipples with
LINOMAX 200.
(Product information for LINOMAX 200 can be requested from
SCHUNK
).
CAUTION
Allergic reactions due to grease in contact with skin!
Wear gloves.
IMPORTANT!
Please regularly check the clamping device for tightness by
applying a clamping force tester over a longer period of time (> 10
min.). The clamping force should not drop during this period.
Please adjust the inspection interval to the operating conditions of
the clamping device, however, we do recommend conducting a
check every 5,000 clamping cycles at the latest
Disassembly and assembly the clamping block
The item numbers specified for the corresponding individual
components relate to chapter drawings.
8
8.1