Assembly
18
03.00|KSF plus, KSF-LH plus, KSF-F plus |en
Connection of the KSF plus and KSF-F plus versions:
The clamping block has two air connections for OPEN: "
I
" and "
III
"
(opening against spring assembly, no turbo function) and an air
bleed screw (sound absorber). The application determines which
of the two air connections (at the front or at the base) must be
opened for actuation:
•
Connection "
I
" for operations with external hose line.
•
Connection "
III
" for air supply to the base side in the machine
table.
Connection of the KSF-LH version:
The clamping block has four air connections: "
I, II, III, IV
". Which of
the two air connections (at the front or at the base) must be
opened for actuation depends on the application:
•
Connections "
I
" and "
II
" for operations with external hose line.
•
Connections "
III
" and "
IV
" for air supply to the base side in the
machine table.
NOTE:
A pneumatic plug-in connection with an M5 connecting thread for
actuating the clamping block can be built in at the thread of the
base side OPEN air supply in the cover (item 5). The hose line must
have a nominal width of min. 6 mm. In KSF-LH, both connections
can be fitted with a pneumatic plug-in connection.
Thread for pneumatic fitting (at the front on housing item 1):
•
KSF plus, KSF-F plus, KSF-LH plus 100: M5
•
KSF plus, KSF-F plus, KSF-LH plus 140, 160, 250: G1/8"
Thread for pneumatic fitting (at the base in cover item 5):
•
All sizes of KSF plus, KSF-F plus and KSF-LH plus: M5
The clamping block is delivered with all four air connections
sealed. On base side with set-screws (item 23) and on front with
locking screws (item 11).
The compressed air used to operate the clamping block must be
dry, filtered and oiled.
Unconditioned compressed air contains dust and oil particles and
moisture, all of which can lead to malfunctions or premature wear
in the clamping block. The oiler should be no more than 2 meters
from the coupling point.