Assembly
74
12.00 | SWS | Assembly and Operating Manual | en | 389456
5.4.3 Mount and check external piston stroke control
CAUTION
The sensor adjustment can be lost!
Do not move or remove sensors from the sensor assembly. The
sensors are preset at the factory.
NOTE
For the sizes SWS 011, SWS 020, SWS 021, SWS 041, SWS 060 and
SWS 071, an external piston stroke control can be attached to the
SWK.
NOTE
Observe requirements when using an adapter plate,
33]. Further information on the adapter
plate design and precise manufacturing instructions can be found
in the catalog data sheet,
7].
5.4.3.1 SWS 011 / 020 / 021
Prepare sensor installation
Ø
Place the SWA in the storage rack, secure and uncouple it.
Ø
Switch off the power supply and ensure that there is no residual
energy in the system.
Ø
Remove the compressed air hose.
Ø
Disassemble the SWK from the robot and safely set the SWK
aside,
Removing the product from the robot arm
Remove cover plate
Ø
Carefully remove the cover plate (1) from the SWK (3). Make
sure that the O-ring (2) remains in the SWK (3).