Assembly
18
01.00|SWS-001 |en
Valve Requirements and Connections
Pneumatic Connections
As with all pneumatic piston arrangements, smooth operation re-
quires proper porting of the supplied and vented air. It is recom-
mended that a single 4-way valve be used to actuate the locking
mechanism in the SWK. The valve may be of either 4-port or 5-port
configuration. It is imperative that when air is supplied to the Lock
or Unlock Port on the SWK, that the opposite port be vented to
atmosphere (i.e., when air is supplied to the Lock Port, the Unlock
Port must be open to the atmosphere.) Failure to vent trapped air
or vacuum on the inactive port will negate the locking force of the
Tool Changer mechanism. The Lock and Unlock Ports are threaded
for M3 connections.
NOTICE
The Tool Changer locking mechanism will not function properly
when connected to a single 3-way valve as this type of valve is
incapable of venting trapped air pressure from within the Tool
Changer.
Connect the Lock and Unlock supply air to a single 4-way valve
with either 4 or 5 port configuration.
6.3.2
Содержание SWS-001
Страница 35: ...Drawings 01 00 SWS 001 en 35 Drawings Tool Changer SWS 001 Tool Changer 11 11 1...
Страница 36: ...Drawings 36 01 00 SWS 001 en quick change head SWK 001...
Страница 37: ...Drawings 01 00 SWS 001 en 37 quick change adapter SWA 001...
Страница 38: ...Drawings 38 01 00 SWS 001 en E04 Electrical Module Electrical Module 11 2...
Страница 40: ...40 01 00 SWS 001 en...