Operation
04.00 | SST | Assembly and operating manual | en | 389581
9
6 Operation
6.1 Installation of a sensor on the sensor tester
6.1.1 Connection of a sensor with connection plug
Ø
Plug the M8 or the M12 plug of the sensor into the according
socket of the SST.
Ø
Tighten the knurled nut.
6.1.2 Connection of a sensor with an open wire strand
Wire colors
for the sensor
Color of SST spring-
type terminal
Description
Brown
Brown (+ PLUS)
Supply voltage of the
VDC
Black / White Black (A)
Sensor signal output
Blue
Blue (– MINUS)
Supply voltage of the GND
sensor
Ø
Check whether the wire colors of the sensor correspond to the
descriptions in the table.
Ø
Connect wires to the spring-type terminals.
6.2 Operation of the SST with a sensor
■
The sensor to be tested is connected.
Ø
Adjust PNP/NPN switch (1) according to the sensor type.
Ø
Actuate the ON button (2).
✓
LED (3) lights up green.
✓
If the LED (3) lights up in red, the battery needs to be
changed.
Ø
If the sensor is damped, the SST emits a signal and the LED (4)
lights up in orange.
Ø
If the status of the sensor changes from damped to undamped,
the SST emits a signal again and the LED (4) goes off.
NOTE
After switching on, the SST remains active for 30 seconds. Every
change of state of the sensor extends the activation duration
another 30 seconds.