Translation of the original manual
Pressure maintenance valve SDV-P
Assembly and Operating Manual
Superior Clamping and Gripping
www.comoso.com
Страница 1: ...Translation of the original manual Pressure maintenance valve SDV P Assembly and Operating Manual Superior Clamping and Gripping www comoso com...
Страница 2: ...4 en SCHUNK GmbH Co KG All rights reserved Dear customer congratulations on choosing a SCHUNK product By choosing SCHUNK you have opted for the highest precision top quality and best service You are g...
Страница 3: ...s and operating conditions 5 2 3 Product safety 6 2 3 1 Protective equipment 6 2 3 2 Constructional changes attachments or modifications 6 2 4 Personnel qualification 6 2 5 Notes on particular risks 7...
Страница 4: ...owing signal words and symbols are used for safety notes DANGER Danger for persons Non compliance will inevitably cause irreversible injury or death WARNING Dangers for persons Ignoring a safety note...
Страница 5: ...irements of the applicable guidelines must be observed and complied with The product may be used only in the context of its defined applica tion parameters 5 Page 8 The product is designed for industr...
Страница 6: ...nt per EC Machinery Directive Constructional changes attachments or modifications Additional drill holes threads or attachments that are not offered as accessories by SCHUNK may be attached only with...
Страница 7: ...on modification maintenance and adjustment the module must be vented Here it is necessary to determine which consumers and which function is triggered so It must be ensured that no person can be injur...
Страница 8: ...The scope of delivery includes Pressure maintenance valve SDV P in the ordered model Technical data Designation SDV P 04 SDV P 07 SDV P 10 connection G1 8 G1 4 G3 8 Max flow l min 200 300 800 Ambient...
Страница 9: ...gy supply The values relate to the entire bolting surface Requirements for levelness of the bolting surface Dimensions in mm Diameter Permissible unevenness 100 0 02 100 0 05 Fig 1 Assembly options 1...
Страница 10: ...sk of injury when removing the air hoses The air hoses at the outputs must be removed carefully be cause they are under pressure even after switching off the power supply Fig 2 Air connection Two chec...
Страница 11: ...Assembly 02 00 SDV P en 11 Fig 3 Further information on the hose free direct connection contains the catalog data sheet circuit diagram www comoso com...
Страница 12: ...sure loss Check the valve for leaks Check the line pressure Maintenance and care The Pressure maintenance valve SDV P is maintenance free If there is leakage or a defect of the mechanical part sent th...