Assembly and installation
44
01.00|PW V6 |en
Set the product to its factory settings
The product can be set to its factory settings by the
DEFAULT
func-
tion.
Adapter board
2
Default
DIP switch
Factory settings/DEFAULT values
Reference value
Axis 1
Axis 2
Interface
RS232
RS232
Baud rate
9600
9600
Address
13
14
1 Disconnect the product from the power supply.
2 Unscrew the cover of the connection cap.
3 Switch
Default
DIP switch (2) to
ON
position.
4 Connect the product to the power supply.
5 Switch
Default
DIP switch (2) to
OFF
position.
6 Disconnect product from the power supply and reconnect again.
7 Screw on the cover of the connection cap.
The product is now reset to its factory settings.