Assembly and installation
36
01.00|PW V6 |en
7 Fix the shielding in place with shrink hose so that the shielding
at the end of the sheath remains visible.
8 Pull the connection cable through the cover (4) or the connec-
tion cap (2) and connect it to the adapter board (3).
9 Pull the metric cable fitting (6) just far enough over the shrink
hose so that the individual wires remain visible.
10 Screw the metric cable fitting (6) to the cover (4) or the con-
nection cap (2).
11 Place the cover (4) on the connection cap (2) and screw it tight.
Combination of multiple products
Combination of multiple products, Profibus and CAN bus
When multiple products are combined, the signals are looped
through from Product n to Product n+1. The wires from Terminal
X2 of the product are clamped in Terminal X1 of Product n+1.
The terminating resistor for CAN bus or Profibus must be set on
the last product,
8.6