![SCHUNK MPZ 16 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/schunk/mpz-16/mpz-16_assembly-and-operating-manual_1215955031.webp)
Assembly
5.3.8 Mounting programmable magnetic switch MMS-IOL
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2), see following table.
1. Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
2. Secure the sensor (1) using the set-screw (4).
Tightening torque: 10 Ncm
3. Adjust sensor (1), see sensor assembly and operating manual.
Dimensions I1
Size
l1* [mm]
Size
l1* [mm]
30
20.0
45
20.0
30 AS
25.5
45 AS
22.75
30 IS
33.5
45 IS
34.5
38
21.0
38 AS
25.5
38 IS
42.0
* Dimen
sion l1
Bottom edge of the product to front edge of the
sensor
31
09.00 | MPZ | Assembly- and Operating Manual | en | 389218