Maintenance and care
02.00 | MLD-L | Montage- und Betriebsanleitung | en | GAS364815
91
7.9 Limit and reference switches
Uninstalling end and reference switches and switch distance
Ø
Unscrew the mounting screws (1) of the switch baseplate (2).
Ø
Unscrew the mounting screws (3) of the switch (4 and 5) and
replace the switch.
Ø
Install the new switch (4 and 6) and adjust the switching
distance to 0.5 mm.
Ø
Tighten the screws (1) on the switch (1) and carry out a test run.