Troubleshooting
40
01.00|1343374_MES3 / MEQ3 / MEW3 |en
Troubleshooting
The clamping areas do not unlock
Possible cause
Remedial measures
Defective air connections
Check air supply
Pressure below minimum
Check operating pressure (min. 5 bar)
A component is broken (e.g. due to
overloading)
Replace the module or send it to SCHUNK for
repair
Excess tensile load on clamping pins
Reduce support weight
The clamping areas do not unlock perfectly
Possible cause
Remedial measures
Pressure below minimum
Check operating pressure (min. 5 bar)
The modules were not operated with
oiled compressed air
Install maintenance unit with oiler
Hose diameter below minimum
for required hose diameters, see chapter
"Securing and connecting"
The turbo connection is still pressurized,
this is applicable for module height
extensions or the clamping station with
turbo function required for mounting
Ventilate the connection
The quick-change pallet systems no longer open quietly
Possible cause
Remedial measures
The clamping faces on the clamping slides
and on the clamping pin are dirty
Remove the clamping pallet and clean the
clamping faces on the clamping slides and on
the clamping pins. Clean all clamping modules
installed on the clamping slides
8
8.1
8.2
8.3
Содержание MEQ3 200-2
Страница 22: ...Assembly 22 01 00 1343374_MES3 MEQ3 MEW3 en MES3 150 1 Set up 1 MEQ3 200 2 Set up 2 ...
Страница 31: ...Assembly 01 00 1343374_MES3 MEQ3 MEW3 en 31 ...
Страница 44: ...Assembly Drawings 44 01 00 1343374_MES3 MEQ3 MEW3 en MES3 120 2 MES3 150 2 MES3 120 2 10 2 ...
Страница 45: ...Assembly Drawings 01 00 1343374_MES3 MEQ3 MEW3 en 45 MEQ3 200 2 MEQ3 200 2 10 3 ...
Страница 46: ...Assembly Drawings 46 01 00 1343374_MES3 MEQ3 MEW3 en MEW3 45 4 MEW3 45 4 10 4 ...