Troubleshooting
20
03.01|LGP 08 - 40|en
Troubleshooting
Modul does not move?
Possible cause
Corrective action
Base jaws jam in housing, possible cause:
bolting surface not sufficiently level.
Check the levelness of the bolting surface.
Loosen the mounting screws for the gripper
and actuate the gripper again.
Pressure drops below minimum.
Compressed air lines switched
Check compressed air lines.
Proximity switch defective or set incorrect. Repair the proximity switch.
Unused air connections not closed.
Close the unused air connections.
Choke valve closed.
Open the choke valve.
Component is broken, e.g. through over-
loading
Replace the module.
The module does not travel through the entire stroke?
Possible cause
Corrective action
Pressure drops below minimum.
Check the air supply.
Mounting surface is not even enough
Check the levelness of the bolting surface.
Component is broken, e.g. through over-
loading
Replace the module.
Module opens or closes abruptly?
Possible cause
Corrective action
Compressed air lines are blocked
Check the compressed air lines for crushing
or damage.
Mounting surface is not even enough
Check the levelness of the bolting surface.
Throttle check valve is missing or not set
correctly
Install and adjust throttle check valve
Load too high
Review permissible weight and length of the
jaws