Assembly and settings
32
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637
5.4.3 Switch-off hysteresis for magnetic switches
Sensors MMS 22, MMS-P 22, MMS 22-PI1 and MMS 22-PI2
The smallest detectable difference in stroke is defined in the
following table:
The smallest detectable difference in stroke based on the nominal stroke
For grippers with X mm
nominal stroke per jaw
Min. query range per jaw/
min. queried stroke difference per jaw
X ≤ 5 mm
30% of the nominal stroke per jaw
X > 5 mm to X ≤ 10 mm
20% of the nominal stroke per jaw
X > 10 mm
10% of the nominal stroke per jaw
Example:
Product with 7 mm nominal stroke per jaw
7 mm * 20% = 1.4 mm
5.4.4 Setting dimensions for position sensors
The setting dimension applies to the following sensors: FPS, APS-
M1, APS-Z80
Setting dimension l3 of the base jaw (2) up to the front of the control cam (1)
Size
Setting dimension l3 [mm]
FPS
APS-M1
APS-Z80
64-1
-0.8
0
+0.7
64-2
-1.1
0
-3.8
80-1
-2
0
0
80-2
-2.6
0
-3.3
100-1
-2.7
0
-1
100-2
-3
0
-3.8
125-1
-3.8
0
+1.7
125-2
-7.8
0
-2.3
160-1
0
0
0
160-2
-4.2
0
-7.1
200-1
+2.2
0
0
200-2
-7.5
0
-3.6
240-1
+4
0
+3
240-2
-8.2
0
-4.6
300-1
-
0
0
Содержание JGP-P
Страница 1: ...Translation of Original Operating Manual Assembly and Operating Manual JGP P 2 finger parallel gripper...
Страница 65: ......
Страница 66: ......
Страница 67: ......