![SCHUNK GSW-B Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/schunk/gsw-b-series/gsw-b-series_assembly-and-operating-manual_1215914019.webp)
Assembly
4.2 Pressure supply
CAUTION
Observe the requirements for the air supply
• Pressure supply with
compressed air
or
machine coolant
is
carried out by the machine spindle.
• If
compressed air
is used:
– On machines
without
check valve: Use screw plug (150).
– On machines
with
check valve: Replace screw plug (150) by
throttle (151).
• If
machine coolant
is used:
– The screw plug (150) must be replaced by the throttle (151).
• Only open the required compressed air connections to the
GSW-B and at the SCHUNK gripper. For hose-free direct
connection, please use the O-ring from the enclosed accessory
kit of the SCHUNK gripper.
• Screw-fit connectors (152) are only used if a SCHUNK TCU
compensation unit is assembled at the same time. The screw-fit
connector is not included in the scope of delivery.
19
05.00 | GSW-B | Assembly and Operating Manual | en | 389112