Assembly
20
02.00 | GSP-P | Assembly and Operating Manual | en | 389033
Types available for order (see catalog):
• MMS-P 22-S-M8-PNP
• MMSK-P 22-S-PNP
• V2-M8-4-2XM8-3
The MMSK-P 22-S-PNP features a cable with open strands so that
it can be connected via terminal contacts.
The V2-M8-4-2XM8-3 distributor is used to convert the 4-pin
connector plug of the MMS-P 22-S-M8-PNP sensor to two
standard M8 plugs with 3 pins each.
Mounting of the
sensor
NOTICE
Sensor can be damaged during assembly.
•
Do not exceed the maximum tightening torque of 10 Ncm for
the set screws!
NOTE
Ferromagnetic material changes the switching positions of the
sensor (e.g. Adapter plate made of ordinary steel).
For ferromagnetic adapter plates:
• The module must be first mounted on the adapter plate.
• Then, the position of the magnetic switchs has to be set.
Ø
To relieve the cable, the electronics have to be fixed in place
using cable ties (7).
There are ribs (6) in place on the electronics for mounting
purposes.