5 Troubleshooting
5.1 Module does not move?
Possible cause
Corrective action
Setscrew/stop screw screwed in too deep
Setscrew for spring adjustment screwed in
too far
Turn back the setscrew (50)
removing and replacing the return spring for
units built before June 2016
5.2 Magnetic switch (MMS) does not work / cannot be adjusted
Possible cause
Corrective action
Steel screws used for fastening the
compensation unit
Replace steel screws with high-alloyed
screws
Mounting plates, angle brackets etc. from
magnetizable materials
Check, replace with nonmagnetizable parts –