Schumacher SpeedCharge 7000A Скачать руководство пользователя страница 4

4

Never

 place charger directly above

battery being charged. The gases from
the battery will corrode and damage the
charger.

Never 

touch the battery clamps together

when the charger is on. You could
cause a spark.

Never 

operate charger if it has received

a hard blow, been dropped, or otherwise
damaged. Take it to a qualified profes-
sional for inspection and repair.

Be sure

 to position the charger power

cord to prevent it from being stepped
on, tripped over, or damaged.

Never

 pull out the plug by the cord

when unplugging the charger. Pulling on
the cord may cause damage to the cord
or the plug.

Do not

 operate the charger if it has a

damaged power cord or plug. Have the
cord replaced.

PERSONAL SAFETY PRECAUTIONS

Wear complete eye and clothing
protection 

when working with lead-

acid batteries.

Make sure 

that someone is within

range of your voice to come to your
aid if needed while you work with or
are near a lead-acid battery.

Have plenty of fresh water and
soap 

nearby for use in case battery

acid contacts your eyes, skin, or
clothing. If this happens, wash
immediately with soap and water.
Then get medical attention.

Avoid touching your eyes 

while

working with a battery. Acid particles
(corrosion) may get into your eyes. If
this occurs, flush eyes immediately
with running cold water for at least 10
minutes. Then immediately get
medical attention.

Never

 charge a frozen battery.

Remove all personal metal items

from your body such as rings,
bracelets, necklaces and watches,
while working with a lead-acid battery.
A battery can produce a short circuit
current high enough to weld a ring (or
the like) to metal, causing a severe
burn.

Take care 

not to drop any metal tool

or metal object onto the battery. This
may spark or short circuit the battery
or another electrical device that may
cause an explosion.

Always 

operate the battery charger in

an open, well-ventilated area.

Never 

smoke or allow a spark or

flame in the vicinity of the battery or
engine. Batteries generate explosive
gases.

Neutralize 

any acid spills thoroughly

with baking soda before attempting to
clean up.

Содержание SpeedCharge 7000A

Страница 1: ...e of this product 0099000417 0204 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 7000A For 12 Volt Batteries computer smart 70 a m p R A P I D C H A R G E a m p E N G I N E S T A R T a m p S L O W C H A R G E 2 20 Send Warranty Product Repairs to Customer Service Returns P O Box 280 1025 E Thompson Hoopeston IL 60942 0280 Questions Call Customer Service 1 800 62...

Страница 2: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that ...

Страница 3: ...ERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary markin...

Страница 4: ... plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching your eyes while working with a battery Acid particles corrosion may get into your eyes If this occurs flush eyes immediately with running cold water for at least 10 minutes Then immediately get medical...

Страница 5: ...ave a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be careful to keep corrosion from getting in or around your eyes Wear safety glasses See additional Personal Safety Precautions on page 4 For batteries with removable vent caps if required add distilled water to each cell ...

Страница 6: ...nds the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the charger unplug its power cord before attempting to disconnect the output clamps Then standing away from the battery remove the output clamp from the chassis or engine block Finally remove the output clamp from the battery post 9 Clean and...

Страница 7: ...24 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 7 To disconnect the Charger unplug its power cord before attempting to disconnect the charger clamps Then standing away from the battery remove the output clamp from the NEGATIVE battery post Finally remove the output clamp from the POSITIVE battery post 8 Clean and store the charger in a dry location US...

Страница 8: ...cycle batteries Not intended for industrial applications 70A START Provides 70 amps for cranking an engine with a weak or run down battery Always use in combination with a battery 7000A CONTROL PANEL BATTERY TYPE SWITCH Use this switch button to set the type of battery to be charged to one of the following three REGULAR This is the type of battery usually used in cars trucks and motorcycles These ...

Страница 9: ...tor tester on good alternator O O 85 130 Alternator tester on bad alternator O O 0 199 2 Amp charge with battery detected O O xx or xx x V 20 Amp charge activated O O xx or xx x V Charge complete Maintain Mode started O 100 or xx x V 70A Engine Start Waiting for engine crank O O O 1 0 16 0 Cranking engine O O 8ĺ Cool down after cranking O B 120ĺ Desulfation mode activated B 15 or 16 V Charge abort...

Страница 10: ...minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTING AFTER CHARGING After the unit has been changed from tester to charger by selecting a charge rate it remains a charger as long as it has power Disconnect and reconnect the power to change the unit back to a tester TESTER STATUS LEDs When the 7000A is operating as a ...

Страница 11: ... The CHARGING yellow LED does not light in the alternator test mode The CHECK red LED lights if the voltage is much higher or lower than normally desired When the tester display mode is set to voltage none of the status LEDs light it could be testing a battery or an alternator ALTERNATOR TESTING NOTES The alternator percent display can range from 0 to 199 The display mode cannot be set to Alternat...

Страница 12: ...harger is very simple First connect the battery and AC power following the precautions listed under OPERATING INSTRUC TIONS Then select the appropriate BATTERY TYPE and CHARGE RATE for your battery The charger will then do everything automatically This section explains a few details CHARGING If the charger does not detect a properly connected battery the CHECK red LED will light continuously until...

Страница 13: ...specific situations CHARGING TIPS If your vehicle won t start You don t need to fully charge a battery to start your vehicle If the charger won t start your vehicle using the 70A START rate try charging the battery using the 20A rate for 10 or 15 minutes That should charge the battery enough to allow the 70A START rate to start the vehicle If the vehicle will then be operated continuously for an e...

Страница 14: ...ted charge rate and eventually reduces the charge rate in a controlled man ner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There are some important facts to keep in mind when charging a battery When the display indicates 77 charged the battery has been charged enough to start most vehicles and has already been ...

Страница 15: ... bank of battery clip Select the batteries requiring more desired charge rate and power than a 20 Amp battery type again if charger can deliver within necessary 24 hours The battery may also be faulty Engine crank time is less Starter motor may be Charge the battery at the than specified drawing more than 70 20A rate for 10 to 15 Amps minutes then crank the engine The green CHARGED The battery may...

Страница 16: ...cturer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WARRANT...

Отзывы: