background image

5

BEFORE USING YOUR BATTERY CHARGER

It is important to understand the charger’s requirements. This section explains the
charger’s electrical requirements and how to prepare a battery for charging.

PLUGGING IT IN

Your charger requires a 120V AC
receptacle installed according to all local
codes and ordinances.

USING AN EXTENSION CORD

The use of an extension cord is not
recommended. If you must use an

extension cord, please make sure that
you follow these guidelines:

• Make sure that pins on plug of

extension cord are the same number,
size, and shape as those of plug on
charger.

• Check that the extension cord is

properly wired and in good electrical
condition.

• Make sure that the wire size is large

enough for its length and for the AC
ampere rating, as specified in the
chart below.

Length of Cord, in Feet

25

50

100

150

AWG* Size of Cord

18

16

12

10

*AWG=American Wire Gauge

MINIMUM RECOMMENDED EXTENSION CORD

PREPARING YOUR BATTERY TO BE CHARGED

It is important that you read and follow these guidelines while you are preparing to
charge the battery.

• Make sure that you have a 12 volt

lead-acid battery. Determine voltage
of battery by referring to vehicle
owner’s manual. Charge battery
initially at charger’s lowest rate.

• Clean the battery terminals. Be

careful to keep corrosion from getting
in or around your eyes.

• Wear safety glasses. See additional

“Personal Safety Precautions” on
page 4.

• For batteries with removable vent

caps, if required, add distilled water to
each cell until the battery acid
reaches the level recommended by
the manufacturer. This will help purge
excessive gases from the cells. Be
careful not to overfill. If you have a
sealed battery with non-removable
vent caps, no action is necessary.

• Take time to read all of the battery

manufacturer’s specific precautions,
such as removing or not removing
vent caps while charging, and
recommended rates of charge.

• Be sure that the area around the

battery is well ventilated while it is
being charged. Gas can be forcefully
blown away by using a piece of
cardboard or other nonmetallic
material as a fan.

• If it is necessary to remove the battery

from the vehicle to charge it, always
remove the grounded terminal from
the battery first. Turn off all vehicle
accessories to avoid sparks from
occurring.

NOTE: 

A marine (boat) battery

installed in a boat must be removed
and charged on shore.

Содержание SpeedCharge 1200A

Страница 1: ... U S A Model 1200A For 12 Volt Batteries SpeedCharge computer smart 8 12a m p F A S T C H A R G E a m p M E D I U M C H A R G E a m p S L O W C H A R G E 2 Fully Automatic Microprocessor Controlled Battery Charger with Battery Tester Send Warranty Product Repairs to Customer Service Returns P O Box 280 1025 E Thompson Hoopeston IL 60942 0280 Questions Call Customer Service 1 800 621 5485 ...

Страница 2: ...is equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different ...

Страница 3: ...m the battery being charged as the charger cables will permit Do not expose charger to rain or snow Never charge a frozen battery If battery fluid electrolyte becomes frozen bring battery into a warm area to allow battery to thaw before you begin charging Never allow battery acid to drip on charger when reading specific gravity or filling battery Never set a battery on top of charger WARNING Handl...

Страница 4: ...fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching your eyes while working with a battery Acid particles corrosion may get into your eyes If this occurs flush eyes immediately with running cold water for at least 10 minutes Then immediately get medical attention ...

Страница 5: ...ave a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be careful to keep corrosion from getting in or around your eyes Wear safety glasses See additional Personal Safety Precautions on page 4 For batteries with removable vent caps if required add distilled water to each cell ...

Страница 6: ...low LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the charger unplug its power cord before attempting to disconnect the output clamps Then standing away from the battery remove the output clamp from the chassis or engine block Finally remove the output clamp from the battery post 9 Clean and store the charger i...

Страница 7: ...ERY 24 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 5 Plug the power cord into an AC outlet The charger will be set to the Tester Mode for REGULAR battery type 6 Press the appropriate control buttons to select the desired charge rate and battery type The CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on ...

Страница 8: ...o be charged to one of the following three 1200A CONTROL PANEL REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent caps and are often marked low maintenance or maintenance free DEEP CYCLE Deep cycle batteries are usually marked as deep cycle or marine Deep cycle batteries are usually larger than the other types AGM GEL CELL AGM and gel cell bat...

Страница 9: ...th no battery O O 0 Voltage meter activated O 0 0 17 0V 2 Amp charge with battery detected O O xx or xx xV 8 Amp charge with battery detected O O xx or xx xV 12 Amp charge with battery detected O O xx or xx xV Charge complete Maintain Mode started O 100 or xx xV Desulfation mode activated B 15 or 16V Charge aborted B 18 8 B User selected User sel User sel User selected User selected User selected ...

Страница 10: ...ter the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTING AFTER CHARGING After the unit has been changed from tester to charger by selecting a charge rate it remains a charger as long as it has power Disconnect and reconnect the power to change the unit back to a tester TESTER STATUS LEDs When the charger is operating as a battery ...

Страница 11: ...l charge If the charger detects a sulfated battery the charger will switch to a special mode of operation designed for such batteries Activation of the special desulfation mode is indicated by blinking the CHARGING LED If successful normal charging will resume after the battery is desulfated The CHARGING LED will then stop blinking and light continuously Desulfation could take up to 10 hours If de...

Страница 12: ...hermocouple This device monitors the temperature and allows the charger to turn the fan on and off as needed If the temperature rises above a preset level the charge current will be reduced to allow the charger to cool If the tem perature can not be reduced at the lower charge rate the charge current will be turned off until the temperature is reduced to a normal level The charger will then contin...

Страница 13: ...te and eventually reduces the charge rate in a con trolled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There are some important facts to keep in mind when charging a battery When the display indicates 77 charged the battery has been charged enough to start most vehicles and has already been charged as mu...

Страница 14: ... power than again if necessary the charger can deliver in 24 hours Battery may also be faulty The green CHARGED light The battery may be fully If the battery is in a vehicle turns on a few minutes after charged or recently charged turn the headlights on for a connecting to the battery leaving the battery voltage few minutes to reduce the high enough to appear to be battery voltage and try fully ch...

Страница 15: ...15 NOTES ...

Страница 16: ...anufacturer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WA...

Отзывы: