BATTERY CHARGER CONTROLS

G

SWlTCH # 1

: Allows you to choose between manual or auto-

matic mode of operation. Automatic offers a selection between
conventional or maintenance-free type batteries. When using
either of the automatic positions set the timer to the hold posi-
tion. If you are not sure which type of battery you have, first
select the conventional position, when the charge complete in-
dicator turns on you may then select the maintenance free posi-
tion. If a maintenance-free battery, the charge complete indica-
tor should turn on, typically within 1 hour, if not you should dis-
continue charging. As an extra measure of safety you may set
the timer for 1 hour.

When charging a battery using the manual mode of operation
use the timer to limit the period of charge. The timer knob will
rotate counter clockwise indicating the remaining time left in the
charge period then automatically turn off.

SWlTCH # 2

: The 2 Amp charge rate is recommended for use

with small batteries only. If used as a trickle charger for large
batteries limit the charge period to a few days at a time. This is a
Manual Charge Only.

SWITCH #3

: The 40 Amp charge rate may be used for fast charg-

ing of all types of larger lead acid batteries. If a battery is less
than half the size of the average automotive battery you should
avoid using the 40 amp rate.

Use the 200 Amp position for crank starting automobiles and
light trucks. Use only in combination with a battery in the vehicle
to reduce the chance of damaging sensitive electronic equip-
ment in the vehicle.

TIMER

: The main function of the timer is to prevent over charg-

ing while allowing a battery time to obtain a satisfactory charge.
To properly set the timer you must know the size of the battery in
ampere hours or reserve capacity in minutes and the state of
charge. Often the state of charge is not known, this is one rea-
sons why the timer was limited to 2.5 hours. with the aid of a
battery load tester the state of charge can be obtained within a
few seconds. For example, the average size automotive battery
at a 50% state of charge will require 1 to 1.5 hours of charging at
the 40 amp rate to reach the full charge state. For the same
battery with the timer set to it’s maximum, 2.5 hours, over charg-
ing will occur, but not likely cause harm to a battery that was
other wise in good condition. When the charge state is not known,
start out with a timer setting of 1 hour or less.

The 

CHARGE INDICATOR LIGHT

 is located within the meter

dial. When a battery reaches full charge the light will turn bright
green. while in the automatic mode of charging the light will turn
on at the appropriate point for a conventional or maintenance
free type battery. While in the manual mode of charging the light
turns on only at the appropriate point for a conventional type
battery. When charging a Maintenance Free battery in the manual
mode of operation, allow an additional 15 to 20 minutes of charg-
ing.

HOLD:

 This position defeats the timer function, allowing for con-

tinuous operation. Use when charging in the automatic mode to
insure that the automatic function has the time required to bring
a battery to full charge. For a battery of questionable condition
the timer can be used in combination with the automatic mode
to guard against a potential problem. When using the 2 Amp
charge rate, most applications will require more time than the
2¼ hours the timer allows.

AMP METER

: The meter indicates the amount of current mea-

sured in amperes that is being drawn by a battery. In the 40 Amp
charge rate a typical discharged battery will initially draw ap-
proximately 40 Amps. As the battery continues to charge, cur-
rent should taper to 15 to 20 Amps at full charge.

The START area of the meter indicates a high rate of current
being drawn from the charger. When cranking an engine the
starter motor draws up-wards to 200 Amps, the meter pointer
will be at the extreme right side of the start area. Some times a
battery for the first few minutes of it’s initial charge will draw
more than 40 Amps, in this case the pointer may be within but,
usually not to the extreme right side of the start area.

When using the 2 Amp rate the meter may indicate some activ-
ity but doesn’t have the resolution to display the battery’s state
of charge.

#1

#2

#3

MANUAL

2 AMP

MANUAL

CHARGE

40/200 AMP

SELECT

200 AMP

START

 AUTOMATIC

 MAINTENANCE-FREE

BATTERY

  CONVENTIONAL

BATTERY

40 AMP

AUTOMATIC

CHARGE

OFF

HOLD

15

30

30

120

135

60

CHARGING

FULL CHARGE

40 AMP RATE

DISCHARGED

40 AMP RATE

FULL CHARGE

(GREEN INDICATOR)

REVERSE

CONNECTION

(RED INDICATOR)

CHARGE RATE

CHARGE TIME/MINUTES

AMP METER

START

0

10

20

30

40

200

Содержание SE-6242A

Страница 1: ...t current high enough to weld a ring or the like to metal causing a severe burn 6 Take care not to drop a metal tool or other metal onto the battery Metal may cause sparking or short circuit the batte...

Страница 2: ...Before using adapter as illustrated be certain that center screw of outlet plate is grounded The green colored rigid ear or lug extending from adapter must be connected to a prop erly grounded outlet...

Страница 3: ...is fully charged unplug charger from AC out let 9 Remove charger clips from 1 chassis and 2 battery post in that order 1 remove clip from end of Negative end of cable and 2 remove clip from Positive...

Страница 4: ...it s maximum 2 5 hours over charg ing will occur but not likely cause harm to a battery that was other wise in good condition When the charge state is not known start out with a timer setting of 1 ho...

Страница 5: ...40 Amp charge rate is chosen then divide 50 AH s by 40 Amps this equal to 1 25 hours or 1 hour and 15 minutes During the charge cycle the 40 Amp charge rate will not remain constant rather as the batt...

Страница 6: ...i entra cido en contacto con sus ojos inmediatamente enju gueselos con agua fr a abundante durante un m nimo de 10 minutos Solicite atenci n m dica de inmediato 5 Qu tese todos los art culos met licos...

Страница 7: ...o a una parte de metal grueso del chasis o al monobloc convencional Al cargar un acumulador del tipo que no que no necesita mantenimiento en el modo de funcionamiento manual permita que cargue 15 a 20...

Страница 8: ...el acumulador est bien ventilada durante la carga Puede sacar el gas del rea sopl ndolo con una hoja de cart n u otro material no met lico usado como abanico G TIEMPO DE CARGA El tiempo aproximado de...

Отзывы: