Schumacher SE-1275A Скачать руководство пользователя страница 5

5

For smaller batteries, 30 AH (ampere hour) or less, use 2
AMP setting. Small batteries may not be able to accept the
potential of the 10 or 12 AMP setting. Unconverted energy will
result in excess heat which the battery may not be able to
dissipate, thus resulting in damage to the battery.

For larger batteries either setting may be used.

CHARGE RATE SWITCH

These chargers are for use with 12 volt lead-acid batteries
only.

OUTPUT VOLTAGE

1.

These battery chargers are equipped with a self-
resetting circuit breaker. This device protects the charger
from temporary overloads. In the event of an overload,
the circuit breaker will trip open, and after a short
cooling off period will reset automatically. this process is
known as cycling and can be recognized by an audible
clicking sound.

2.

These battery chargers are equipped with an electronic
control circuit which automatically governs the charge
rate to your battery. The charger will satisfactorily
charge Maintenance Free and Conventional batteries.

OPERATION INSTRUCTIONS

FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE

A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION.  TO REDUCE RISK Of A SPARK NEAR BATTERY:

1.

Check polarity of battery posts. POSITIVE (POS, P,+)
battery post usually has a larger diameter than NEGA-
TIVE (NEG, N, -) post.

2.

Attach at least a 24-inch-long 6-gauge (AWG) insulated
battery cable to NEGATIVE (NEG, N, -) battery post (
not
provided).

3.

Connect POSITIVE (RED) charger clip to POSITIVE
(POS, P,+) post of battery.

4.

Position yourself and free end of cable as far away from
battery as possible - then connect NEGATIVE (BLACK)
charger clip to free end of cable.

5.

Do not face battery when making final connection.

6.

When disconnecting charger, always do so in reverse
sequence of connecting procedure and break first
connection while as far away from battery as practical.

7.

A marine (boat) battery must be removed and charged
on shore. To charge it on board requires equipment
specially designed for marine use.

POSITIVE

NEGATIVE

CHARGER

POWER

CORD

TO GROUNDED

POWER OUTLET

24" 6 GAUGE

CABLE

BATTERY

FIGURE 8  CONNECT NEGATIVE BATTERY

             CLIP TO 24 INCH CABLE END

AC POWER CORD CONNECTION INSTRUCTIONS

J.

This battery charger is for use on a nominal 120-volt
60 HZ circuit.

DANGER - Never alter AC cord or plug provided - if it will not
fit outlet, have proper outlet installed by a qualified  electri-
cian. Improper connection can result in a risk of an electric
shock.

K.

L.

M.

N.

Содержание SE-1275A

Страница 1: ...C INPUT RATING AMPERES AWG SIZE OF CORD Equal to or but less than Length of Cord Feet Greater than 25 50 100 150 0 2 18 18 18 16 2 3 18 18 18 14 6 8 18 16 12 10 9 Do not operate charger with damaged c...

Страница 2: ...gases from battery will corrode and damage charger 3 Never allow battery acid to drip on charger when reading gravity or filling battery 4 Do not operate charger in a closed in area or restrict ventil...

Страница 3: ...tart to assist in engine cranking of 12 volt systems DO NOT use on 6 volt systems Use the 50 amp engine start position for cranking automobiles or light trucks Use only with battery in the vehicle Thi...

Страница 4: ...e period for length of charge information FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE GROUND NEG FIGURE 7 CONNECTION TO NEGATIVE GROUNDED BATTERY DC CONNECTION PRECAUTIONS 2 Attach clips t...

Страница 5: ...SE BATTERY EXPLOSION TO REDUCE RISK Of A SPARK NEAR BATTERY 1 Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than NEGA TIVE NEG N post 2 Attach at least a 24...

Страница 6: ...ours by the number of AMPS supplied to a load For example If a load was connected to a battery which drew 7 AMPS for a period of 5 hours the battery will have supplied 35 AH The approximate recharge t...

Страница 7: ...n turn on Charger will not turn OFF Battery has problem and will Have battery checked not take full charge Meter needle pulses Two or more batteries Do not parallel charge fluctuates every few connect...

Страница 8: ...voltaje de la bater a de acuerdo al Manual del carro y aseg rese que el interruptor de selecci n de voltaje marque el voltaje correcto Si la bater a tiene una proporci n de carga ajustable empiece por...

Страница 9: ...ONVENCIONALES DE BAJO MANTENIMIENTO Selector 1 L MANUAL AUTOMATICO PARA BATERIAS LIBRES DE MANTENIMIENTO Y DE CICLAJE PROFUNDO M M Selector 2 SELECCION DE CARGA L L 10 AMPS 2 AMPS OPERACIONES PARA EL...

Страница 10: ...ro o motor lejos de la bater a No conecte los alicates al carburador lineas de gasolina u hojas de metal del cuerpo del carro Conecte un metal fuerte del marco del bloque del motor 6 Para veh culos qu...

Страница 11: ...e carga baja a 4 AMP s el cargador se apaga Inicialmente el voltaje de la bater a baja al estado de 15 AMP r pidamente Cuando llega a 13 voltios el cargador arrancar de nuevo hasta llegar a 15 voltios...

Страница 12: ...la bater a en pocos segundos y entonces el cargador debe encenderse El cargador no se APAGA La bater a tiene problema y no acepta Haga revisar la bater a plena carga La aguja del amperimetro pulsa Hay...

Отзывы: