Schumacher SC-12000A SpeedCharge Скачать руководство пользователя страница 13

12

BATTERY PERCENT AND CHARGE TIME

This charger adjusts the charging time in 

order  to  charge  the  battery  completely, 

efficiently  and  safely. The  microproces

-

sor  automatically  makes  the  necessary 

decisions. However, this section includes 

guidelines  that  can  be  used  to  estimate 

charging times.
The duration of the charging process de-

pends on three factors:

1.

 Battery State

 – If a battery has only 

been slightly discharged, it can be 

charged in less than a few hours. 

The same battery could take up to 10 

hours if very weak. The battery state 

can be estimated by using the built-in 

tester (see page 12). The lower the 

reading the longer charging will take.

2.

 Battery rating

 – A higher rated 

battery will take longer to charge 

than a lower rated battery under the 

same conditions. A battery is rated in 

ampere-hours (AH), reserve capacity 

(RC) and cold cranking amps (CCA). 

The lower the rating the quicker the 

battery will be charged.

3.

 Charge rate 

– The charge rate is 

measured in amps. This charger pro-

vides charge rates of 2A, 15A



40A. 

The 120A rate is for engine start only. 

The

 

2A rate is for charging smaller 

batteries such as those used for mo-

torcycles and garden tractors. Such 

batteries should not be charged using 

the REGULAR BATTERY setting. 

The 15A



40A rates are for charg-

ing larger batteries. In the REGULAR 

BATTERY mode, the charger begins 

at the 15A rate and increases the 

charge rate if it is determined that 

the battery can accept the 40A rate. 

All charging modes will decrease the 

charge rate as the battery approaches 

maximum charge. 

After the charging process has started, the 

digital display can be used to determine 

charging progress by selecting the BAT-

TERY % mode.
There are some important facts to keep in 

mind when charging a battery.

•  When the display indicates 77% 

charged, the battery has been charged 

enough to start most vehicles and has 

already been charged as much as by 

many other battery chargers.

•  When the display indicates 85% 

charged, the battery has already been 

charged at least as much as by most 

other battery chargers.

•  The battery % shown in tester mode 

is an estimate based on the bat-

tery voltage and the Battery Council 

International scale. The battery % 

shown in charger mode is an estimate 

of the relative charge in the battery 

compared to the charge it should have 

if the charging process is allowed to 

complete.

•  The battery % shown in tester mode 

can be used to estimate the relative 

charge time. The lower the % shown, 

the longer the charge time for a given 

battery. 

•  The battery % shown in charger mode 

is an indication of the relative progress 

of the charging process. The higher 

the battery % displayed, the less 

charge time remains.

•  The more a battery is discharged, 

the faster it absorbs charge from a 

charger. That means that the battery 

% increases faster at the beginning 

of the charging process than at the 

end. In other words, it takes longer 

for the battery to absorb the last few 

percent of charge than the first several 

percent. 

Содержание SC-12000A SpeedCharge

Страница 1: ...duct 00 99 000620 0206 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model SC 12000A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Return...

Страница 2: ...refully IMPORTANT SAFETY INSTRUCTIONS 2 PERSONAL SAFETY PRECAUTIONS 3 BEFORE USING YOUR BATTERY CHARGER 3 Plugging It In 3 Assembling Your Charger 3 Using An Extension Cord 4 PREPARING YOUR BATTERY TO...

Страница 3: ...N FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY save these Instructions To reduce risk of electrical shoc...

Страница 4: ...running cold water for at least 10 minutes Then immediately get medi cal attention Remove all personal metal items from your body such as rings brace lets necklaces and watches while working with a l...

Страница 5: ...ies to avoid sparks from occurring NOTE A marine boat battery installed in a boat must be removed and charged on shore Using an extension cord The use of an extension cord is not rec ommended If you m...

Страница 6: ...ound ed or connected to the chassis THIS IS NORMALLY THE NEGATIVE POST 7 Press the appropriate control buttons to select the desired charge rate and battery type Within a few seconds the CHARGING yell...

Страница 7: ...s not start wait 3 minutes before cranking again 3 Aftertheenginestarts unplugthepower cord before disconnecting the output clamps from the battery 4 Clean and store the charger in a dry location Note...

Страница 8: ...by blinking the CHARGING LED If successful nor mal charging will resume after the battery is desulfated The CHARGING LED will then stop blinking and light continuously Desulfation could take up to 10...

Страница 9: ...e specialized vehicles The6V REGULAR batterytypeisnotselectableforbatteries greater than 8 5V DC With the exception of AGM and gel cell batteries all other battery types may or may not have vent caps...

Страница 10: ...99 Alternator tester on good alternator O O O 0 199 Alternator tester on bad alternator O O 0 199 Small Battery 2A charge activated O O O xx or xx xV Regular Battery 15A 40A charge activated O O O xx...

Страница 11: ...y is connected In that case the charger will be set for the small battery charge rate and 12V regular battery type TESTER WITHOUT TIME LIMIT If either the DIGITAL Display or Bat tery Type button is pr...

Страница 12: ...n the digital display or press the digital display button to set the tester to Alternator and read the alternator percent using the built in alternator tester TESTER STATUS LEDs When the SC 12000A is...

Страница 13: ...e rate if it is determined that the battery can accept the 40A rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started the...

Страница 14: ...ur vehicle you don t need to wait for the entire charging process to be completed When the charger displays a battery of 77 or more see page 14 the battery has usually been charged enough for the vehi...

Страница 15: ...ours May be due to a very large battery or a bank of batteries requiring more power than a 15A 40A amp charger can deliver within 24 hours The bat tery may also be faulty Reset the charger by briefly...

Страница 16: ...er or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THI...

Страница 17: ...0 0206 MANUAL DEL DUE O Schumacher Electric Corporation Mount Prospect IL 60056 U S A Modelo SC 12000A Para Bater as de 6 y 12 voltios Env e los productos para Reparaci n bajo Garant a a Customer Serv...

Страница 18: ...Bater a sacada del Veh culo 5 C mo Usar el Arranque de Motor 6 C MO USAR SU CARGADOR DE BATER AS 7 CONTROLES DEL CARGADOR 8 GU A AL PANEL DE CONTROL 9 EL USO DEL PROBADOR DE BATER AS INCORPORADO 10 E...

Страница 19: ...bida ventilaci n El aire necesita fluir alred edor del cargador entero No coloque el cargador sobre materiales inflamables tales como alfombras tapizado papel GUARDE ESTAS INSTRUCCIONES cart n etc El...

Страница 20: ...ador de bater as en un sector abierto y bien ventilado Nuncafumenipermitaquehayachispao llamacercadelabater aodelmotor Las bater as generan gases explosivos Neutralice minuciosamente cualquier derrame...

Страница 21: ...n pedazo de cart n u otro material no met lico Si resulta necesario sacar la bater a del veh culo para poderla cargar siempre quite primero el terminal a tierra de la bater a Apaguetodoslosaccesoriosd...

Страница 22: ...el cord n de potencia antes de tratar de desconectar las pinzas del cargador Luego par ndose alejado de la bater a quite la pinza de salida del poste NEGATIVO de la bater a Finalmente quite la pinza...

Страница 23: ...puesto en uno de tres estados 1 Espere el arranque El cargador espera hasta que se comience el ar ranqueantesdeentregar120amperios para poner el motor en marcha El car gador entrega a una tasa hasta p...

Страница 24: ...ar se indica por el encender y apagar del LED CHARGING amarillo Si hay xito el proceso normal de cargar comenzar de nuevo despu s de que la bater a quede desulfurada El LED CHARGING en tonces dejar de...

Страница 25: ...menudo est n marcadas low main tenance mantenimiento bajo o main tenance free sin maintenimiento 12V DEEP CYCLE CICLO PRO FUNDO Lasbater asdecicloprofundo normalmente vienen marcadas deep cycle o mari...

Страница 26: ...r r a n q u e d e m o t o r Pantalla Digital Encendido inicial bater a battery no detectada O O 0 0 No bater a o bater a invertida detectada 0 or 0 0V Probador de bater a activada O 0 100 Probador de...

Страница 27: ...apaga y se activa el probador L MITE DE TIEMPO INACTIVO AL INICIO DE POTENCIA Si no se oprima ning n bot n dentro de los 15 minutos despu s de que se encienda inicial mente el SC 12000A autom ticamen...

Страница 28: ...alles con unas pocas diferencias SECUENCIA DE PROBAR Hay tres pasos b sicos requeridos para usar el SC 12000A en forma de probador de alternadores 1 Conectelaspinzasdebater adelcarga dor de bater as a...

Страница 29: ...minaquelabater apuedeaceptarla tasa de 40A Todos los modos de cargar har ndisminuirlatasadecargaamedida que la bater a se acerque a la carga m xima Despu s de haber comenzado el proceso de cargar la p...

Страница 30: ...se complete el ciclo entero de cargar Cuando el cargador muestra un de bater a de 77 o m s vea la p gina 14 la bater a por lo general se ha cargado lo suficiente para que el veh culo se ponga en march...

Страница 31: ...ectuosa Para reponer el cargador desench felo brevemente y desconecte la pinza neg ativa de la bater a Escoja la tasa de carga deseada SMALL o REGULAR BAT TERY y BATTERY TYPE de nuevo al ser necesa ri...

Страница 32: ...otra garant a aparte de la presente garant a limitada y expresamente excluye cualquier garant a impl cita inclusive garant a por da os con secuentes LA PRESENTE GARANT A ES LA NICA GARANT A EXPRESA Y...

Отзывы: