Connecting Your PI-1500
to turn oN:

1.  Push the rocker switch, located on the right side, to the 

“oN” (I) position. The led indicator light should glow 

GReeN verifying the inverter is receiving power and can 

deliver power to your device. (A brief audio alarm may 

sound or red LED may flash. This is normal.) 

2.   Turn on the power source or device to be powered.

Note:

 If more than two devices are to be powered, start 

one device at a time to avoid a power surge and overload-

ing the inverter. The surge load of each device should not 

exceed 1500 watts. 
You can use an extension cord from the inverter to the 

device without significantly decreasing the power being 

generated by the inverter. For best operating results, the 

extension cord should be no longer than 50 feet.

to turn oFF: 

1.  Push the rocker switch, located on the right side, to the 

“oFF” (o) position. 

2.  Turn off the power source and the device.
3.  disconnect inverter from power source and device.
4.  Wait  for  the  inverter  to  be  cool  to  the  touch  before 

disconnecting it from the power source. 

 

Note:

 The PI-1500 inverter and device should always 

be unplugged when not in use.

Содержание PI-1500

Страница 1: ...12V DC Battery Power to 110V AC Home Power SAVE THESE INSTRUCTIONS The recommended source of power is a 12 volt deep cycle battery due to their high reserve power capacity Automotive batteries are re...

Страница 2: ...fects or other reproductive harm Wash hands after handling Important Safety Measures Precautions to keep in mind before and while using your power inverter For the most effective use place the power i...

Страница 3: ...he power inverter to a 12 volt battery Con necting to a 6V or 16V battery will cause damage to the inverter Only connect the power inverter to a 12 volt battery with the supplied 12 volt power cords M...

Страница 4: ...inverter The PI 1500 must be used with devices drawing 1500 watts or less If the wattage is not marked on the device an estimate can be made by multiplying the AC input current Amps by the AC voltage...

Страница 5: ...mportant Make sure you connect your inverter to a 12 volt power supply only Connecting to another voltage including any AC power source will result in damage Do not try extending or otherwise changing...

Страница 6: ...ion in power C Two 110V GFCI AC Outlets D One Pair 12 Volt Power Cords E Two High Speed Cooling Fans keeps inverter cool The speed of the fan is faster as the load increases Fan does not run when inve...

Страница 7: ...one washer 3 Strip the insulation of the wire back 1 5 inches and in between the two washers wrap the bare end of the 8 AWG copper wires around the threaded screw extension 4 Holding the wire in plac...

Страница 8: ...rminal and bare end of the negative black cable into the negative terminal Tighten each terminal screw so the cable cannot come loose Connecting Inverter Cables To 12V Battery Or 12V Power Source 1 Ke...

Страница 9: ...rload ing the inverter The surge load of each device should not exceed 1500 watts You can use an extension cord from the inverter to the device without significantly decreasing the power being generat...

Страница 10: ...n Note If the light or other product remains ON when the Test button is pushed the GFCI is not working properly and should not be used Call Customer Service The PI 1500 includes two GFCI Ground Fault...

Страница 11: ...ge range of 15 5V 0 5V DC too high for inverter Voltage exceeding 16 volts may damage the inverter Reduce voltage range to 12 volts to 14 volts Voltage Shortage Alarm sounds indicating voltage is gett...

Страница 12: ...he positions of the inverter antenna cables and television power cord Add an extension cord from the inverter to the TV so as to isolate its power cord and antenna cables from the 12 volt power source...

Страница 13: ...g placed by the equipment being operated with the inverter If you decide to use the inverter while the engine is off turn OFF the device plugged into the inverter before starting the engine Start the...

Страница 14: ...fitted with cooling fans that run as needed while the inverter is operating If the cooling fans are unable to maintain a cool enough temperature for safe operation the inverter will automatically shu...

Страница 15: ...nals Unhook and rehook the 12 volt connections 2 Using incorrect type of voltmeter to test output voltage Use a true RMS reading meter PROBLEM Red LED On Reason Solution 1 Battery voltage below 11 vol...

Страница 16: ...harge or replace battery PROBLEM Device Does Not Work Reason Solution 1 Device does not turn on Try turning the inverter ON then OFF then ON again Contact the device manufacture for start up surge and...

Страница 17: ...al user or consumer purchaser If your inverter malfunctions or fails within the 12 month warranty period because of a defect in material or workmanship we will repair it without charge or replace it T...

Страница 18: ...hould be prop erly packed to avoid damage in transit since we will not be responsible for any such damage In no event shall Schumacher Electric Corporation be liable for consequential damages Some sta...