ESPECIFICACIONES

Modelo: PID-500-USB

 

Máxima energía continua ................................................................500 Watts 
Capacidad de tensión (potencia máxima) .....................................1000 Watts 
Consumo de corriente en vacío ............................................................

<0,4A

 

Forma de onda ......................................................

Onda senoidal modificada

 

Ámbito de tensión de entrada

 ............................................

10,5V a 15,5V DC

 

Ámbito de tensión de salida

 ...................................................... 120V±5% AC 

Alarma de batería baja

 .........................................

Audible, 10,7V a 11,3V CD

 

Cierre por batería baja

 ...........................................................

10,5V±0,5V DC

 

Óptima eficiencia

 ................................................................................... >80%

Modelo: PID-750

 

Máxima energía continua ................................................................750 Watts 
Capacidad de tensión (potencia máxima) .....................................1500 Watts 
Consumo de corriente en vacío ............................................................

<0,4A

 

Forma de onda ......................................................

Onda senoidal modificada

 

Ámbito de tensión de entrada

 ............................................

10,5V a 15,5V DC

 

Ámbito de tensión de salida

 ...................................................... 120V±5% AC 

Alarma de batería baja

 .........................................

Audible, 10,7V a 11,3V CD

 

Cierre por batería baja

 ..........................................................

10,5V± 0,5V DC

 

Cierre por batería alta

 ........................................................

15,0V a 16,0V DC

 

Óptima eficiencia

 ................................................................................... >80%

PIEZAS DE REPUESTO

Modelo: PID-500-USB

 

Clavija accesoria de 12 V con cables

 ......................................... 3899001511 

Cable de batería con abrazaderas

 ..............................................3899001512

Modelo: PID-750

 

Cable de batería con abrazaderas

 ..............................................3899001534

Содержание PID-500-USB

Страница 1: ...UAL DEL USUARIO PID 500 USB PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE This manual will explain how to use the converter safely and effectively Please read and follow these instructions a...

Страница 2: ......

Страница 3: ...EPAIRS 12 LIMITED WARRANTY 13 WARRANTY CARD 27 CONTENIDOS INSTRUCCIONES IMPORTANTES DE SEGURIDAD 14 PRECAUCIONES DE SEGURIDAD PERSONAL 15 ANTES DE USAR SU CONVERTIDOR 15 PARA CONECTAR LOS CABLES DEL C...

Страница 4: ...f it has received a sharp blow been dropped or otherwise damaged in any way take it to a qualified service person Do not disassemble the converter take it to a qualified service person when service or...

Страница 5: ...rve capacity Automotive batteries are recommended for only a short period of time of an hour or less Do not use the converter with a product that draws a higher wattage than the converter can provide...

Страница 6: ...evices we strongly recommend that you use caution and check the device s manual to make sure it is compatible with modified sine waveform 1 Switch mode power supplies 2 Linear power supplies 3 Class 2...

Страница 7: ...TO 12V BATTERY OR 12V POWER SOURCE PID 500 USB and PID 750 1 Keep hands hair clothing and jewelry clear of battery terminals 2 Wear eye protection and clothing protection 3 Connect the negative black...

Страница 8: ...signals Below are some suggestions to try and improve reception 1 Try altering the position of the converter antenna cables and television power cord Add an extension cord from the converter to the T...

Страница 9: ...drain HOW POWER CONVERTERS WORK There are two stages involved in transforming 12 volt DC battery power into 120 volt AC household voltage STAGE 1 The power converter uses a DC to DC transformer to inc...

Страница 10: ...a qualified technician for repair TROUBLESHOOTING PROBLEM POSSIBLE CAUSE REASON SOLUTION Alarm is on Display shows Device demands too much surge power Device has a short circuit Display shows 12 volt...

Страница 11: ...ooling Converter does not turn on Poor contact at terminals Fuse is blown Check for poor connection to battery or power supply Make sure connection points are clean Rock clamps back and forth for a be...

Страница 12: ...Low battery alarm Audible 10 7V 11 3V DC Low battery shutdown 10 5V 5V DC Optimum efficiency 80 REPLACEMENT PARTS Model PID 500 USB 12V Accessory plug with cable 3899001511 Battery cable with clamps 3...

Страница 13: ...d by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or statutory warranti...

Страница 14: ...erior al permitido No utilice el convertidor si el mismo recibi un golpe fuerte si se cay o si sufri da os de cualquier otra forma h galo revisar por una persona capacitada que efect e reparaciones No...

Страница 15: ...grave NUNCA fume o permita la presencia de chispas o llamas en la proximidad de una bater a o motor ANTES DE USAR SU CONVERTIDOR Este convertidor ha sido dise ado para ser usado con una sola bater a h...

Страница 16: ...recto a la bater a NOTA El l mite de 100 watts es para adaptar la proporci n del fusible a todos los veh culos Algunos veh culos pueden permitir la salida Si el fusible se funde cuando cambie al apara...

Страница 17: ...olamente CONEXI N DEL CONVERTIDOR NOTA Para el modelo PID 500 USB determine si usara las abrazaderas de la bater a salida m xima de 500 watts o la clavija accesoria de 12 V m ximo 120 watts 1 Ubique l...

Страница 18: ...ser operado este APAGADO OFF 5 Conecte el dispositivo en la toma de corriente CA del convertidor 6 Encienda el dispositivo El LED de Salida de Energ a brillar y el visualizador digital mostrar O 7 En...

Страница 19: ...de escuchar un sonido de zumbido siendo emitido de sistemas de sonido baratos cuando son operados con el convertidor Esto es debido a filtros inefectivos en el abastecimiento de energ a del sistema de...

Страница 20: ...se genera por esta conversi n VISUALIZADOR LED El visualizador LED identifica el estado actual del convertidor VOLTAJE DE ENTRADA El voltaje de la bater a del veh culo el arrancador de Energ a Port ti...

Страница 21: ...un cortocircuito El visualizador muestra La bater a de 12V est demasiado baja El visualizador muestra el voltaje entre 10 5 y 11 0V El visualizador muestra El voltaje de 12V est demasiado alto Cicle...

Страница 22: ...se enciende Mal contacto en las terminales El fusible est quemado Revise por una mala conexi n a la bater a o abastecimiento de energ a Aseg rese de que los puntos a conexi n est n limpios Balancee l...

Страница 23: ...delo PID 750 M xima energ a continua 750 Watts Capacidad de tensi n potencia m xima 1500 Watts Consumo de corriente en vac o 0 4A Forma de onda Onda senoidal modificada mbito de tensi n de entrada 10...

Страница 24: ...convertidor por un plazo de dos 2 a os contados a partir de la fecha de compra por menor por la existencia de cualquier material o de mano de obra defectuosos que pudieran surgir por su uso y cuidado...

Страница 25: ...las garant as excepto la garant a limitada incluida en el presente por medio de la presente quedan expresamente anuladas y excluidas Algunos estados no permiten la exclusi n ni la limitaci n de los d...

Страница 26: ...26...

Страница 27: ...ation 801 Business Center Drive Mount Prospect IL 60056 2179 Name_______________________________________________________________ Street Address________________________________________________________...

Страница 28: ...orporation 801 Business Center Drive Mount Prospect IL 60056 2179 Nombre_____________________________________________________________ Direcci n_________________________________________________________...

Отзывы: