5.3. Resetting a
SAFE-O-TRONIC
with the "ResetKey"
Clearing a
SAFE-O-TRONIC
may be necessary for example if a mistake was made in initializing
(e.g. wrong cabinet number) or if a
SAFE-O-TRONIC
needs to have a different configuration.
NOTE
The ResetKey is only accepted by the
SAFE-O-TRONIC
if it is unlocked
!
The
megalock
is reset in the following way:
1. Activate
megalock
(push rotary knob)
2. You have 8 seconds to hold the ResetKey in front of the rotary knob in the sensing zone
of the
SAFE-O-TRONIC
antenna.
Once the parameters in the
SAFE-O-TRONIC
have been cleared, the
SAFE-O-TRONIC
acknowledges the process by causing the green LED to come on for a brief time followed
by simultaneous flashing of the green and red LED.
3. Now the
SAFE-O-TRONIC
can be reconfigured with a SetupKey
(see: 5.2. Configuring the
SAFE-O-TRONIC
with the "SetupKey").
5.4. Replacing a
SAFE-O-TRONIC
If it becomes necessary to replace a
SAFE-O-TRONIC
, the new
SAFE-O-TRONIC
must first
:
1. be configured with the
megalock
number and other parameters using the SetupKey
(see: 5.2. Configuring the
SAFE-O-TRONIC
with the "SetupKey") and
2. be actuated with a MasterKey to ensure that the new
SAFE-O-TRONIC
accepts only
MasterKeys having the currently valid MasterKey-Generation.